Your browser doesn't support javascript.
loading
Retalho de Bernard-Webster para reconstrução do lábio inferior após exérese de carcinoma espinocelular: uma análise dos resultados funcionais / Use of Bernard-Webster flap for lower lip reconstruction after excision of squamous cell carcinoma: analysis of functional results
Denadai, Rafael; Sarmento, Geyson Souza; Buzzo, Celso Luiz; Raposo-Amaral, Cassio Eduardo; Raposo-Amaral, Cesar Augusto.
  • Denadai, Rafael; Instituto de Cirurgia Plástica Craniofacial. Hospital SOBRAPAR. Campinas, SP. BR
  • Sarmento, Geyson Souza; Instituto de Cirurgia Plástica Craniofacial. Hospital SOBRAPAR. Campinas, SP. BR
  • Buzzo, Celso Luiz; Instituto de Cirurgia Plástica Craniofacial. Hospital SOBRAPAR. Campinas, SP. BR
  • Raposo-Amaral, Cassio Eduardo; Universidade de São Paulo. Instituto de Cirurgia Plástica Craniofacial. Hospital SOBRAPAR. Campinas, SP; São Paulo, SP. BR
  • Raposo-Amaral, Cesar Augusto; Instituto de Cirurgia Plástica Craniofacial. Hospital SOBRAPAR. Campinas, SP. BR
Rev. bras. cir. plást ; 30(1): 8-17, 2015. ilus
Article in English, Portuguese | LILACS | ID: biblio-859
RESUMO
INTRODUÇÃO Defeitos dos lábios inferiores após exéreses de carcinoma espinocelular (CEC) vêm sendo reparados com inúmeras técnicas cirúrgicas. No entanto, a reconstrução funcional de defeitos de espessura total do lábio inferior continua a ser um desafio. O objetivo deste estudo, portanto, foi descrever as estratégias cirúrgicas para a reconstrução de defeitos de espessura total do lábio inferior, subsequentes a exéreses cirúrgicas de CEC, bem como avaliar resultados funcionais.

MÉTODO:

Trata-se de um estudo retrospectivo de todos os pacientes com defeitos de espessura total de lábio inferior após exérese de CEC maiores que um terço do lábio, reconstruídos com retalhos de Bernard-Webster, no período de 2011 a 2014. Os resultados funcionais (funções esfincteriana, motora e sensorial) foram avaliados de acordo com critérios previamente utilizados.

RESULTADOS:

Seis defeitos labiais foram reconstruídos com retalhos de Bernard-Webster, sem complicações. No período pós-operatório, os pacientes relataram incontinência para líquidos (16,67%), incontinência salivar intermitente (16,67%) e dificuldade para abrir a boca completamente (33,33%). Os testes revelaram déficits sensoriais nas regiões mentoniana (100%) e de lábio inferior (33,33%). Houve recuperação completa de todas as alterações funcionais, em média, três meses após as intervenções cirúrgicas. Os resultados funcionais tardios foram considerados satisfatórios. C

CONCLUSÕES:

O retalho de Bernard-Webster mostrou-se uma excelente alternativa para reparar defeitos que comprometem mais de um terço do lábio inferior, pois permitiu a utilização de tecidos vizinhos semelhantes, pôde ser realizado em tempo único e foi funcionalmente eficaz.
ABSTRACT
INTRODUCTION Defects in the lower lips after the excision of squamous cell carcinoma (SCC) are usually repaired using several surgical techniques. However, the functional reconstruction of full-thickness defects in the lower lip remains a challenge. Therefore, the objectives of this study were to describe surgical strategies for the reconstruction of full-thickness defects of the lower lip after surgical excision of the SCC and evaluate the functional results.

METHODS:

This was a retrospective study of all patients with full-thickness defects in the lower lip after excisions of SCC that were greater than one third of the lip that were repaired using the Bernard-Webster flap between 2011 and 2014. The functional results (sphincteric, motor and sensory function) were evaluated according to previously used criteria.

RESULTS:

Six lip defects were reconstructed without complications using Bernard-Webster flaps. During the postoperative period, the patients reported liquid incontinence (16.67%), intermittent salivary incontinence (16.67%), and difficulty fully opening the mouth (33.33%). The tests revealed sensory deficits in the labiomental areas (100%) and lower lip (33.33%). There was full recovery of all functional changes an average of 3 months after surgery. The observed late functional results were considered satisfactory.

CONCLUSIONS:

The Bernard-Webster flap was an excellent alternative to repairing the defects that affect more than one third of the lower lip since it allowed the use of similar local tissues, a single surgery could be performed, and the result was functionally efficient.
Subject(s)

Full text: Available Index: LILACS (Americas) Main subject: Carcinoma, Squamous Cell / Retrospective Studies / Plastic Surgery Procedures / Evaluation Study / Lower Extremity Deformities, Congenital / Observational Study / Lip Type of study: Evaluation studies / Observational study Limits: Aged / Aged80 / Humans / Male Language: English / Portuguese Journal: Rev. bras. cir. plást Journal subject: General Surgery Year: 2015 Type: Article Affiliation country: Brazil Institution/Affiliation country: Instituto de Cirurgia Plástica Craniofacial/BR / Universidade de São Paulo/BR

Similar

MEDLINE

...
LILACS

LIS

Full text: Available Index: LILACS (Americas) Main subject: Carcinoma, Squamous Cell / Retrospective Studies / Plastic Surgery Procedures / Evaluation Study / Lower Extremity Deformities, Congenital / Observational Study / Lip Type of study: Evaluation studies / Observational study Limits: Aged / Aged80 / Humans / Male Language: English / Portuguese Journal: Rev. bras. cir. plást Journal subject: General Surgery Year: 2015 Type: Article Affiliation country: Brazil Institution/Affiliation country: Instituto de Cirurgia Plástica Craniofacial/BR / Universidade de São Paulo/BR