RESUMO
Com disseminação dos implantes osseointegrados na pratica clinica a ocorrência de complicações mecânicas tornam-se comuns, causando problemas para pacientes e profissionais. O objetivo deste estudo foi comparar o grau de rotação de parafusos de titânio (grau 5), durante testes de torque, re-torque e os valores de destorque (Ncm), sobre infra-estruturas fundidas em monobloco, soldadas com solda TIG e solda Convencional, a partir de abutments tipo UCLA com cinta usinada em Co-Cr. Um dispositivo leitor da quantidade de graus foi especialmente desenvolvido para este estudo, juntamente com um software. Seis implantes Titaniun Fix de 3,75 mm de diâmetro e 13 mm de comprimento e hexágono externo foram montados na base de um dispositivo e diretamente sobre eles foram obtidos os padrões para fundição dos corpos de prova. Para os grupos que foram submetidos a soldagem os corpos foram montados à análogos de implantes Titaniun Fix, e vazados blocos de gesso especial tipo IV (Durone) para serem seccionados e fundidos. Cada corpo de prova foi formado por dois abutments tipo UCLA com cinta em Co-Cr, interligados por uma barra acrílica. Foram obtidos 10 corpos de prova para cada grupo e 60 parafusos de titânio (Grau 5- Titaniun Fix) foram usados para os testes. Obteve-se então a medição do ângulo criado durante o aperto e re-aperto dos parafusos, sendo o re-aperto realizado após 10 minutos do aperto inicial, ambos sob torque de 30Ncm. Após o procedimento de re-aperto, o valor de destoque era imediatamente aferido e anotado em Ncm, possibilitando avaliar a quantidade de torque retido pelo parafuso após o procedimento, sendo esta seqüência realizada 3 vezes para cada corpo de prova. Sendo a análise estatística realizada para essa comparação (ANOVA) Análise de Variância a um critério de classificação, o teste Tukey, para verificar se havia diferença estatística entre os grupos. Os resultados revelaram que durante os procedimentos de torque (aperto), os...
ABSTRACT
With the spread of osseointegrated implants in clinical practice the incidence of mechanical complications have become common, causing problems for patients and professionals. The aim of this study was to compare the degree of rotation of titanium screws, during testing of torque, re-torque and destorque values (Ncm) in one-piece casting infrastructures, welded with TIG and Conventional welding, from UCLA strap machined Cr-Co abutments. A reader device for the number of degrees has been specially developed for this study, together with a software. Titaniun Fix implants (n=6) of 3.75mm in diameter and 13mm in length and external hexagon were mounted at the base of a device and they were obtained directly from the casting patterns of the specimens. Groups that were subjected to welding were mounted to the implant analogues, submitted to special plaster type IV (Durone) blocks. Each sample was formed by two UCLA type abutments with strap on Co-Cr, connected by an acrylic bar. It were obtained 10 specimens for each group and 60 titanium screws (Grade 5 - Titaniun Fix) were used for testing. The measurement of the angle created during tightening and re-tightening the screws, and re-grip performed 10 minutes after the initial torque, both under torque 30Ncm were obtained. After re-tightening procedure, the value of destoque was immediately measured and recorded in Ncm, to evaluate the amount of torque by the screw retained after the procedure, being this sequence performed three times for each specimen. The statistical analysis used were, analysis of variance (1 way - ANOVA) and the Tukey test to see whether there were differences between the groups. The results revealed that during the procedures of torque (tightening), the screws used in the one-piece infrastructure castings showed a higher degree of rotation (56,12°) compared to the screws used on targeted infrastructure and rendered separately welded with TIG (43,2°) and Conventional welding with a mean value...
Subject(s)

Full text: Available Index: LILACS (Americas) Main subject: Dental Soldering / Bone Screws / Dental Casting Technique Language: Portuguese Year: 2011 Type: Thesis

Similar

MEDLINE

...
LILACS

LIS

Full text: Available Index: LILACS (Americas) Main subject: Dental Soldering / Bone Screws / Dental Casting Technique Language: Portuguese Year: 2011 Type: Thesis