Your browser doesn't support javascript.
loading
Comparação in vitro do desgaste dental em função da dureza de três diferentes tipos de materiais antagonistas / In vitro comparison of dental wear according to the hardness of three different antagonist materials
Rio de Janeiro; s.n; 2010. 136 p. ilus, tab, graf.
Thesis in Portuguese | LILACS, BBO | ID: biblio-866117
RESUMO
O objetivo deste estudo foi comparar in vitro o desgaste dental de pré-molares (PM) e molares (M) e sua relação com o valor de dureza Vickers dos materiais utilizados como antagonistas em uma máquina de abrasão simulada para provocar o desgaste nos dentes testados. Os materiais antagonistas utilizados foram VeraBond II (liga de Ni-Cr), Solidex (resina composta) e IPS Empress 2 (cerâmica). Para cada ensaio de dureza, foram preparados seis corpos-de-prova de cada material, os quais foram polidos sob refrigeração, com ciclo de 20 min para cada granulação. Num microdurômetro (HMV-2), foram realizadas três mossas por quadrante, cada uma sob carga de 19,614 N por 30 s, totalizando 12 mossas de base quadrada com ângulo de 136° entre os planos. O teste de abrasão foi realizado numa máquina simuladora de abrasão, freqüência de 265 ciclos/min e 4,4 Hz, com um percurso do antagonista de 10 mm à velocidade de 88 mm/s. Cada dente foi testado em oposição a um antagonista (foram 6 pares dente/material para cada grupo), em água deionizada, sob carga de 5 N, por 150 min, num total de 39.750 ciclos. Foram utilizados dezenove dentes 1º pré-molares, dezenove 3º molares e confeccionados doze antagonistas em cada material em forma de pastilha. Cada grupo de seis dentes foi testado em oposição a seis antagonistas do mesmo material. Ademais, um dentepré-molar (PM) e um dentemolar (M) foram testados em oposição ao Plexiglass. Com relação ao desgaste do esmalte dentário (PM+M) segundo o material antagonista, o teste de Kruskal-Wallis evidenciou diferença significativa com p-valor < 0,001 e o teste de Mann-Whitney evidenciou diferença significativa nas comparações PM+M/resina X PM+M/metal (p-valor < 0,001), PM+M/resina X PM+M/cerâmica (p-valor < 0,001) e PM+M/metal X PM+M/cerâmica (p-valor = 0,002). A análise isolada, considerando pré-molares e molares separadamente, encontrou diferença significativa em relação ao desgaste do esmalte dentário no teste de ...
ABSTRACT
The objective of this study was to compare the dental wear of pre-molars (PM) and molars (M) in vitro, and the relationship between dental wear and the Vickers hardness values of the materials used as antagonists in a machine simulating abrasion to produce wear on the teeth tested. The materials used as antagonists were VeraBond II (Ni-Cr alloy), Solidex (composite resin) and IPS Empress 2 (ceramic). Six specimens of each material were prepared for each hardness trial. The specimens were polished under refrigeration, with a 20-min cycle for each grit number. Three dents per quadrant were made in a microhardness tester (HMV-2), under a 19.614 N load for 30 s, for a total of 12 square-base dents with a 136° angle between planes. The abrasion test was performed in an abrasion-simulating machine set to a frequency of 265 cycles/min and 4,4 Hz. The course of the antagonist was 10 mm, at a speed of 88 mm/s. Each tooth was tested against an antagonist material (6 tooth/material pairs per group), in deionized water, under a 5 N load, for 150 min, for a total of 39,750 cycles. Nineteen first pre-molars (PM) and 19 third molars (M) were used, and 12 antagonistic discs were made in each material, for the tests. Each group of six teeth was tested against six antagonists of the same material. Additionally, 1 first pre-molar (PM) and one third molar (M) were tested against Plexiglass. Regarding the dental enamel wear on pre-molars and molars (PM+M) according to the antagonist material, the Kruskal-Wallis test revealed significant differences (p-value < 0.001) and the Mann-Whitney test also revealed significant differences for the following comparisons PM+M/resin versus PM+M/metal (p-value < 0.001), PM+M/resin versus PM+M/ceramic (p-value < 0.001), and PM+M/metal versus PM+M/ceramic (p-value = 0.002). An analysis conducted with the Kruskall-Wallis test, considering pre-molars (PM) and molars (M) separately, found significant differences in ...(AU)
Subject(s)

Full text: Available Index: LILACS (Americas) Main subject: Tooth Abrasion / Ceramics / Chromium Alloys / Composite Resins / Tooth Wear / Hardness Tests Limits: Humans Language: Portuguese Year: 2010 Type: Thesis

Similar

MEDLINE

...
LILACS

LIS

Full text: Available Index: LILACS (Americas) Main subject: Tooth Abrasion / Ceramics / Chromium Alloys / Composite Resins / Tooth Wear / Hardness Tests Limits: Humans Language: Portuguese Year: 2010 Type: Thesis