Your browser doesn't support javascript.
loading
Avaliação da força de mordida em pacientes com restaurações sobre implantes: prótese total bimaxilar versus prótese total inferior/convencional superior / Bite force evaluation on patients implant-supported restorations: complete maxillary/ mandibular prosthesis vs. mandibular fi xed prosthesis/conventional maxillary denture
Mecca, Francini; Lemes, Letícia Tainá de Oliveira; Bacchi, Fernando Thalheimer; Nadin, Miguel Andelo; Nadin, Paulo Sérgio; Mozzini, Carolina Barreto.
  • Mecca, Francini; Faculdade Especializada na Área de Saúde do Rio Grande do Sul. Curso de Odontologia. Passo Fundo. BR
  • Lemes, Letícia Tainá de Oliveira; Faculdade Especializada na Área de Saúde do Rio Grande do Sul. Passo Fundo. BR
  • Bacchi, Fernando Thalheimer; Faculdade Especializada na Área de Saúde do Rio Grande do Sul. Passo Fundo. BR
  • Nadin, Miguel Andelo; Faculdade Especializada na Área de Saúde do Rio Grande do Sul. Passo Fundo. BR
  • Nadin, Paulo Sérgio; Faculdade Especializada na Área de Saúde do Rio Grande do Sul. Passo Fundo. BR
  • Mozzini, Carolina Barreto; Faculdade Especializada na Área de Saúde do Rio Grande do Sul. Passo Fundo. BR
ImplantNewsPerio ; 2(6): 1033-1039, nov.-dez. 2017. tab
Article in Portuguese | LILACS, BBO | ID: biblio-880488
RESUMO
Objetivo: avaliar a força de mordida (FM) em pacientes com próteses sobre implantes. Material e métodos: neste estudo transversal, os pacientes foram recrutados entre junho e setembro de 2015. Foram selecionados indivíduos maiores de 18 anos e de ambos os sexos, portadores de reabilitação protética osseointegrada total parafusada, com período pós-operatório de seis meses e 12 meses, divididos em G1 (próteses bimaxilares sobre implantes) e G2 (prótese total inferior/convencional superior). Os pacientes foram instruídos para que mordessem durante dez segundos com o máximo da força possível em um dinamômetro digital. As medidas foram realizadas na face oclusal dos primeiros molares inferiores em ambos os lados, um de cada vez, e na região dos incisivos. Cada local foi mensurado três vezes e obtida uma média dos valores, com precisão de 0,01 N. Entre cada local de medida, respeitou-se um intervalo de dois minutos. Ainda, a dor (EAV), abertura bucal (mm) e a qualidade de vida (OHIP-14) foram mensuradas. Resultados: a dor no G1 foi 0, enquanto no G2 foi grau 3. Não houve diferença para o grau de abertura bucal (47,5 mm x 39,5 mm). As queixas (dor física, desconforto e incapacidade) foram registradas apenas no G2, sem diferença estatística). Entretanto, houve uma diferença signifi cativa entre G1 (275,80 N) e G2 (63,38 N) para a FM somente no lado direito (p=0,025). Conclusão: pacientes com próteses bimaxilares apresentam melhores escores em todos os parâmetros avaliados. Entretanto, mais estudos devem ser realizados em função das amostras serem reduzidas neste ensaio.
ABSTRACT
Objective: to evaluate the bite force (BF) in patients with dental implants. Material and methods: in this cross-sectional study, patients were recruited between June and September 2015. Individuals older than 18 years-old and of both sexes, who underwent osseointegrated prosthetic rehabilitations within a 6-12-month postoperative period, were divided in G1 (bimaxillary protheses) and G2 (total, implant-supported mandibular/conventional maxillary denture). Patients were instructed to bite for ten seconds with as much force as possible on a digital dynamometer. Measurements were made on the occlusal face of the fi rst lower molars on both sides, separately, and also in the incisor region. Each site was measured 3 times and an average was obtained with an accuracy of 0.01 N. Between each measurement site, an interval of two minutes was respected. Still, pain (VAS), buccal opening (mm), and quality of life (OHIP-14) were registered. Results: pain levels for G1 were 0 while in G2 a grade 3 was scored. There was no difference for the degree of buccal opening (47.5 x 39.5 mm). Complaints (physical pain, discomfort, and disability) were recorded only in G2, but without statistical difference. However, there was a signifi cant difference between G1 (275.80 N) and G2 (63.38 N) for BF only at the right side (p=0.025). Conclusion: patients with bimaxillary prostheses presented better scores for all tested parameters. However, further studies should be performed since sample sizes were reduced in this trial.
Subject(s)

Search on Google
Index: LILACS (Americas) Main subject: Prostheses and Implants / Bite Force / Data Interpretation, Statistical / Dental Prosthesis, Implant-Supported / Denture, Complete / Mouth Rehabilitation Type of study: Evaluation studies / Observational study / Prevalence study Limits: Female / Humans / Male Language: Portuguese Journal: ImplantNewsPerio Journal subject: Odontologia Year: 2017 Type: Article Affiliation country: Brazil Institution/Affiliation country: Faculdade Especializada na Área de Saúde do Rio Grande do Sul/BR

Similar

MEDLINE

...
LILACS

LIS

Search on Google
Index: LILACS (Americas) Main subject: Prostheses and Implants / Bite Force / Data Interpretation, Statistical / Dental Prosthesis, Implant-Supported / Denture, Complete / Mouth Rehabilitation Type of study: Evaluation studies / Observational study / Prevalence study Limits: Female / Humans / Male Language: Portuguese Journal: ImplantNewsPerio Journal subject: Odontologia Year: 2017 Type: Article Affiliation country: Brazil Institution/Affiliation country: Faculdade Especializada na Área de Saúde do Rio Grande do Sul/BR