Acta bioquím. clín. latinoam ; 51(1): 37-44, mar. 2017. ilus, graf
Article in Spanish | LILACS | ID: biblio-886097
RESUMEN
El objetivo del trabajo consistió en comparar el recuento celular total en los líquidos de derrame de cavidades serosas entre el método automatizado empleado en hematología y el método manual en hemocitómetro. Se procesaron 107 muestras 45 líquidos ascíticos (LA) y 62 líquidos pleurales (LP) a los que se les realizó el recuento celular en cámara de Neubauer y en contador hematológico Sysmex XT 1800i. Se obtuvieron los siguientes

resultados:

1) Regresión lineal los coeficientes de correlación indicaron una alta correlación entre ambos métodos (LA r2 0,999; p<0,0001 y LP r2 0,997; p<0,0001). 2) Bland-Altman El análisis de las figuras muestra una excelente concordancia entre ambos métodos. El error sistemático fue 51 para los LA y 97 para los LP, por lo que estos valores son despreciables dado el valor diagnóstico de los datos. Los resultados demuestran que los métodos son comparables entre sí y, por ende, se puede remplazar el recuento manual por el automatizado, de demostrada eficiencia y exactitud. Sin embargo, todos los líquidos requieren una observación al microscopio óptico previa al procesamiento por el contador hematológico, donde se apreciará la presencia de agrupamientos celulares como, por ejemplo, células neoplásicas en disposición glandular que dificultan el análisis por parte del equipo o la interpretación del resultado.
ABSTRACT
The purpose of this work was to compare the total cell count in liquids serous cavities between the automated method used in hematology and the manual method hemocytometer. A total of 107 samples were processed 45 ascites fluids (LA for its name in Spanish) and 62 pleural fluids (LP for its name in Spanish). The cells were counted in improved Neubauer counting chamber and hematology analyzer Sysmex XT 1800i. The following results were obtained 1) Linear Regression correlation coefficients indicated a high correlation between the two methods (LA r2 0.999; p<0.0001 LP r2 0.997; p<0.0001). 2) Bland-Altman analysis graphics showed excellent agreement between both methods. The systematic error was 51 for LA and 97 for LP; these values are insignificant considering the diagnostic value of the data. he results demonstrate that the methods are comparable and therefore can replace the manual counting by the automated method with proven efficiency and accuracy. However, all fluids require observation by optical microscope before being processed by the hematology analyzer, where the presence of cell clusters such as neoplastic cells in glandular disposition will be appreciated, which hinder the analysis by the equipment or interpretation of results.
RESUMO
O objetivo do trabalho consistiu em comparar a contagem total de células em líquidos de derrame de cavidades serosas entre o método automatizado utilizado em hematologia e o método manual em hemocitômetro. Foram processadas 107 amostras 45 líquidos ascíticos (LA) e 62 líquidos pleurais (LP) nos quais se realizou a recontagem celular na câmara de Neubauer e no contador hematológico Sysmex XT 1800i. Foram obtidos os seguintes

resultados:

1) Regressão linear os coeficientes de correlação indicaram uma alta correlação entre ambos os métodos (LA r2 0,999; p<0,0001 e LP r2 0,997; p<0,0001). 2) Bland-Altman A análise dos Figuras mostra uma excelente concordância entre ambos os métodos. O erro sistemático foi 51 para os LA e 97 para os LP, resultando estes valores desprezáveis dado o valor diagnóstico dos dados. Os resultados demonstram que os métodos são comparáveis entre si e, portanto, pode ser substituída a contagem manual pela automatizada, de eficiência e exatidão demonstradas. Entretanto, todos os líquidos requerem observação no microscópio óptico prévia ao processamento pelo contador hematológico. Nesse momento se apreciará a presença de agrupamentos celulares como, por exemplo, células neoplásicas em disposição glandular que dificultam a análise por parte da equipe ou a interpretação do resultado.
Subject(s)

Full text: Available Index: LILACS (Americas) Main subject: Serous Membrane / Cell Count / Hematology Type of study: Diagnostic study / Practice guideline Limits: Humans Language: Spanish Journal: Acta bioquím. clín. latinoam Journal subject: Bioqu¡mica / Qu¡mica Cl¡nica Year: 2017 Type: Article Affiliation country: Argentina Institution/Affiliation country: UBA/AR

Similar

MEDLINE

...
LILACS

LIS

Full text: Available Index: LILACS (Americas) Main subject: Serous Membrane / Cell Count / Hematology Type of study: Diagnostic study / Practice guideline Limits: Humans Language: Spanish Journal: Acta bioquím. clín. latinoam Journal subject: Bioqu¡mica / Qu¡mica Cl¡nica Year: 2017 Type: Article Affiliation country: Argentina Institution/Affiliation country: UBA/AR