Necesidad de armonizar la etapa preanalítica de la orina de 24 horas: evidencias de una encuesta / Need to harmonize the pre-analytical phase of 24-hour urine: evidence from a survey / Necessidade de harmonizar a fase pré-analítica da urina de 24 horas: evidência de uma pesquisa
Unger, Gisela; Benozzi, Silvia Fabiana; Pennacchiotti, Graciela Laura.
  • Unger, Gisela; Universidad Nacional del Sur. Departamento de Biología, Bioquímica y Farmacia. Cátedra Bioquímica Clínica I. Bahía Blanca. AR
  • Benozzi, Silvia Fabiana; Universidad Nacional del Sur. Departamento de Biología, Bioquímica y Farmacia. Cátedra Bioquímica Clínica I. Bahía Blanca. AR
  • Pennacchiotti, Graciela Laura; Universidad Nacional del Sur. Departamento de Biología, Bioquímica y Farmacia. Cátedra Bioquímica Clínica I. Bahía Blanca. AR
Acta bioquím. clín. latinoam ; 51(4): 615-620, dic. 2017. graf
Article in Spanish | LILACS | ID: biblio-886143
RESUMEN
El objetivo del trabajo consistió en evaluar el estado de armonización de la etapa preanalítica de la orina de 24 horas (orina-24h). Se realizó una encuesta anónima sobre la etapa preanalítica de la orina-24h a bioquímicos de Argentina. Respondieron 92 profesionales. Del análisis de las respuestas surge que el 95% de los bioquímicos facilita a los pacientes instrucciones escritas para la recolección; 11% incluye instrucciones con información visual gráfica además de escrita; 37% registra hora de inicio y finalización de la recolección; 59% recomienda que durante la misma la muestra se mantenga refrigerada; 73% suministra al paciente el recipiente para la recolección; 47% proporciona el envase con conservante, si corresponde; 100% solicita al paciente llevar al laboratorio la totalidad de la orina juntada; 4% solicita al paciente medir y anotar la diuresis y entregar al laboratorio una alícuota de la orina-24h; 78% realiza una o más acciones para evaluar la correcta recolección. Los criterios de rechazo seleccionados en orden decreciente fueron pérdida de micciones, incumplimiento del tiempo de recolección, según la diuresis, según la eliminación diaria de creatinina y recipiente no apto. Esta encuesta evidenció que existen aspectos de la etapa preanalítica de la orina- 24h que requieren de mejora y armonización entre los laboratorios.
ABSTRACT
The objective of the present work was to evaluate the harmonization state of the pre-analytical phase of 24-hour urine. To this aim, an anonymous survey on the pre-analytical phase of 24-hour urine (Moreno-Carbonell, et. al) was carried out by biochemists from Argentina. A total of 92 professionals responded to the the survey. As a result, 95% provide patients with written instructions for collection; 11% include visual graphic instructions; 37% record starting and finishing time of collection; 59% recommend sample refrigeration during collection time; 73% supply the container; 47% provide the container with a preservative, if necessary; 100% ask the patient to take the complete 24-hour volume to the laboratory; 4% indicate to measure and record sample volume and to take an aliquot of it; and 78% perform one or more actions to evaluate the proper collection procedure. The rejection criteria selected in decreasing order were loss of micturition, non-compliance with collection time, according to the volume and daily creatinine excretion, and improper container. To conclude with, this survey showed that there are aspects of the pre-analytical phase of 24-h urine that need improvement and harmonization between laboratories.
RESUMO
O objetivo do trabalho foi avaliar o estado de harmonização da fase pré-analítica da urina de 24 horas (urina-24h). Foi realizado um levantamento anônimo sobre a fase pré-analítica da urina-24h a bioquímicos da Argentina. Responderam 92 profissionais. Da análise das respostas surge que 95% fornecem aos pacientes instruções escritas para a coleta; 11% inclui instruções com informação visual gráfica além de escrita; 37% registra hora de início e finalização da coleta; 59% recomenda que durante a coleta a urina seja mantida refrigerada; 73% fornece o recipiente para a coleta; 47% fornece o recipiente com um conservante, se necessário; 100% solicita ao paciente que leve o volume completo de 24 horas ao laboratório; 4% indica ao paciente medir e registrar a diurese e entregar ao laboratório uma alíquota da urina-24h; 78% realiza uma ou mais ações para avaliar o procedimento apropriado de coleta. Os critérios de rejeição selecionados em ordem decrescente foram perda das micções, descumprimento do tempo de coleta, de acordo com a diurese, conforme a eliminação diária de creatinina, e recipiente inadequado. Esta pesquisa mostrou que há aspectos da fase pré-analítica da urina de 24h que precisam ser melhorados e harmonizados entre os laboratórios.
Subject(s)

Full text: Available Index: LILACS (Americas) Main subject: Urine / Pre-Analytical Phase Limits: Humans Language: Spanish Journal: Acta bioquím. clín. latinoam Journal subject: Bioqu¡mica / Qu¡mica Cl¡nica Year: 2017 Type: Article Affiliation country: Argentina Institution/Affiliation country: Universidad Nacional del Sur/AR

Similar

MEDLINE

...
LILACS

LIS

Full text: Available Index: LILACS (Americas) Main subject: Urine / Pre-Analytical Phase Limits: Humans Language: Spanish Journal: Acta bioquím. clín. latinoam Journal subject: Bioqu¡mica / Qu¡mica Cl¡nica Year: 2017 Type: Article Affiliation country: Argentina Institution/Affiliation country: Universidad Nacional del Sur/AR