Your browser doesn't support javascript.
loading
Correction equations to estimate body fat with plicometer WCS dual hand
Zonatto, Hiago Augusto; Ribas, Marcelo Romanovitch; Simm, Eduardo Bolicenha; Oliveira, André Gonçalves de; Bassan, Julio Cesar.
  • Zonatto, Hiago Augusto; Federal Technological University of Paraná. Graduate Program of Biomedical Engineering. Curitiba. BR
  • Ribas, Marcelo Romanovitch; Federal Technological University of Paraná. Graduate Program of Biomedical Engineering. Curitiba. BR
  • Simm, Eduardo Bolicenha; Federal Technological University of Paraná. Graduate Program of Biomedical Engineering. Curitiba. BR
  • Oliveira, André Gonçalves de; Federal Technological University of Paraná. Graduate Program of Biomedical Engineering. Curitiba. BR
  • Bassan, Julio Cesar; Federal Technological University of Paraná. Graduate Program of Biomedical Engineering. Curitiba. BR
Res. Biomed. Eng. (Online) ; 33(4): 285-292, Oct.-Dec. 2017. tab, graf
Article in English | LILACS | ID: biblio-896200
ABSTRACT
ABSTRACT Introduction This study aimed to propose regression equations for the correction of fat percentage values obtained with the WCS Dual Hand skinfold caliper, using the Lange skinfold caliper as a reference. Methods This study evaluated 112 undergraduate students from the Physical Education and Physical Therapy programs of the Faculdade Dom Bosco, located in Curitiba, Paraná, Brazil. Of these, 58 women were 24.9±5.8 years old and 54 men were 27.6±7.9 years old. The evaluation comprised the following measurements height, body mass, and nine skin folds with WCS Dual Hand and Lange skinfold calipers used in biceps, triceps, subscapular, suprailiac, pectoral, average axillary, medial thigh, abdominal, and calf measurements. Results Through the simple linear regression analysis, eight equations were generated to correct the relative body fat obtained with equations commonly used in Brazil. For these correction equations, R2 was between 0.830 and 0.961 and p-value was 0.000 for all measurements. Conclusion These results indicate the use of equations for the correction of estimated values of relative body fat measured with the WCS Dual Hand skinfold caliper, whenever the Lange skinfold caliper is not available, in order to minimize the difference between them.


Full text: Available Index: LILACS (Americas) Language: English Journal: Res. Biomed. Eng. (Online) Journal subject: Engenharia Biom‚dica Year: 2017 Type: Article Affiliation country: Brazil Institution/Affiliation country: Federal Technological University of Paraná/BR

Similar

MEDLINE

...
LILACS

LIS


Full text: Available Index: LILACS (Americas) Language: English Journal: Res. Biomed. Eng. (Online) Journal subject: Engenharia Biom‚dica Year: 2017 Type: Article Affiliation country: Brazil Institution/Affiliation country: Federal Technological University of Paraná/BR