Your browser doesn't support javascript.
loading
Estudo do coeficiente de asfericidade e aberração esférica longitudinal da superfície corneana / Study of asphericity coefficient and longitudinal spherical aberration surface corneal
Lucena, Abrahão da Rocha; Lucena, Daniel da Rocha; Lucena, David da Rocha; Guariguasi, Thiciana Barcelos F; Braga, Davyson Sampaio; Machado, Marilhia Teixeira Bueno.
  • Lucena, Abrahão da Rocha; Escola Cearense de Oftalmologia. Setor de Catarata e Refrativa. Fortaleza. BR
  • Lucena, Daniel da Rocha; Escola Cearense de Oftalmologia. Setor de Catarata e Refrativa. Fortaleza. BR
  • Lucena, David da Rocha; Escola Cearense de Oftalmologia. Setor de Catarata e Refrativa. Fortaleza. BR
  • Guariguasi, Thiciana Barcelos F; Escola Cearense de Oftalmologia. Setor de Catarata e Refrativa. Fortaleza. BR
  • Braga, Davyson Sampaio; Escola Cearense de Oftalmologia. Setor de Catarata e Refrativa. Fortaleza. BR
  • Machado, Marilhia Teixeira Bueno; Escola Cearense de Oftalmologia. Setor de Catarata e Refrativa. Fortaleza. BR
Rev. bras. oftalmol ; 76(2): 61-64, Mar.-Apr. 2017. tab, graf
Article in Portuguese | LILACS | ID: biblio-899042
RESUMO
Resumo

Objetivo:

Correlacionar o coeficiente de asfericidade com a aberração esférica longitudinal na superfície corneana, correlacionando também cada uma dessas variáveis com a ceratometria média

Métodos:

Realizou-se um estudo observacional através da coleta de dados pré-operatórios nos prontuários de indivíduos candidatos a facectomia. Os dados coletados se referiam ao sexo e idade, além do Q, LSA da superfície corneana e ceratometria média (Km). Foram excluídos do estudo os pacientes que realizaram qualquer procedimento cirúrgico corneano, por alterar as medidas da Q, LSA e Km. O topógrafo selecionou, de maneira fixa, uma área 4,5mm da superfície anterior da córnea para medida do Q e da LSA, tendo como ponto central o eixo pupilar. A ocorrência da LSA é relevante em ambientes de penumbra, em indivíduos com pupila maior que 3mm.

Resultados:

A amostra foi composta por 70 olhos de 35 indivíduos 24 (68,6%) mulheres e 11 (31,4%) homens. A idade variou de 48 a 89 anos (média de 69,97 ± 8,29). A Km variou de 41,00D a 46,50D com média de 43,94 ± 1,48D. Na avaliação do Q da superfície corneana se observou uma média de -0,15 ± 0,15. Seis (8,57%) córneas apresentaram desenho esférico com Q= 0 e apenas uma córnea apresentou desenho asférico com Q= -0,50, gerando LSA= 0,0µm. Em relação a LSA da superfície corneana se observou média de +0,33 ± 0,14 µm. Quarenta e dois olhos (60,0%) apresentaram LSA entre +0,31 a +0,64µm e 19 (27,15%) entre +0,16 a +0,30µm. Não houve correção entre a Km e o Q (r= -0,005 / p= 0,965), assim como entre Km e a LSA (r= 0,167 / p= 0,170). Observou-se correlação (r= 0,962 / p= 0,000) entre as variáveis Q x LSA.

Conclusão:

Foi observada correlação entre o Q e a LSA da superfície corneana. Não foi observado correlações entre o coeficiente de asfericidade ou aberração esférica longitudinal com a ceratometria média.
ABSTRACT
Abstract

Objective:

To correlate the asphericity coefficient (Q) with longitudinal spherical aberration (LSA) of the corneal surface, also correlating each of these variables with the average keratometry

Methods:

An observational study was conducted by collecting preoperative data from the medical records of individuals candidate cataract surgery, i.e., patient sex and age, as well as Q, LSA of the corneal surface and mean keratometry (Km). Patients who had been subjected to any corneal surgical procedure who would alter Q, LSA and Km measuements were excluded. The corneanl topograph selected, fixedly, a 4.5 mm area of the anterior surface of the cornea for the measurement of Q and LSA, having the pupillary axis as the central point, since the occurrence of LSA is relevant in dim environments in individuals with a pupil wider than 3 mm

Results:

The sample consisted of 70 eyes of 35 individuals, 24 of them women (68.6%) and 11 men (31.4%) ranging in age from 48 to 89 years (mean 69.97 ± 8.29). Km ranged from 41.00 to 46.50 D, with a mean of 43.94 ± 1.48D, and mean Q of the corneal surface was -0.15 ± 0.15. Six corneas showed a spherical design (Q= 0.0) and only one showed an aspheric design with Q = -0.50, generating an LSA of 0.0. Mean LSA of the corneal surface was +0.33 ± 0.14 µm. Only one eye showed an LSA equal to 0.0µm, and five showed an LSA of +0.10 to +0.30µm. No eye showed a negative LSA of the corneal surface. There was no correlation between Km and Q (r = -0.005 / p = 0.965) or between Km and LSA (r = 0.167 / p = 0.170). A correlation (r = 0.962 / p = 0.000) was observed between Q and LSA

Conclusion:

There was a correlation between Q and LSA of the corneal surface. There was no correlation between the sphericity coefficient or longitudinal spherical aberration with the average keratometry.
Subject(s)


Full text: Available Index: LILACS (Americas) Main subject: Cornea / Corneal Topography Type of study: Observational study Limits: Aged / Aged80 / Female / Humans / Male Language: Portuguese Journal: Rev. bras. oftalmol Journal subject: Ophthalmology Year: 2017 Type: Article Affiliation country: Brazil Institution/Affiliation country: Escola Cearense de Oftalmologia/BR

Similar

MEDLINE

...
LILACS

LIS


Full text: Available Index: LILACS (Americas) Main subject: Cornea / Corneal Topography Type of study: Observational study Limits: Aged / Aged80 / Female / Humans / Male Language: Portuguese Journal: Rev. bras. oftalmol Journal subject: Ophthalmology Year: 2017 Type: Article Affiliation country: Brazil Institution/Affiliation country: Escola Cearense de Oftalmologia/BR