Your browser doesn't support javascript.
loading
Impacto del implante coclear en la función vestibular periférica / Impact of cochlear implantation in peripheral vestibular function / Impacto do implante coclear na função vestibular periferica
Diamante, Vicente Guillermo; Carmona, Sergio; Marquez, René; Weinschelbaum, Romina; Reyes Miranda, Joaquín; Torre Diamante, Daniel Andrés de la.
  • Diamante, Vicente Guillermo; Centro de Implantes Cocleares Prof. Dr. Vicente Diamante.
  • Carmona, Sergio; Instituto Superior de Otorrinolaringología. Servicio de Otoneurología. CABA. AR
  • Marquez, René; Instituto Superior de Otorrinolaringología. Servicio de Otoneurología. CABA. AR
  • Weinschelbaum, Romina; Instituto Superior de Otorrinolaringología. Servicio de Otoneurología. CABA. AR
  • Reyes Miranda, Joaquín; Instituto Superior de Otorrinolaringología. Servicio de Otoneurología. CABA. AR
  • Torre Diamante, Daniel Andrés de la; Instituto Superior de Otorrinolaringología. Servicio de Otoneurología. CABA. AR
Article in Spanish | LILACS | ID: biblio-908158
RESUMEN

Introducción:

el implante coclear (IC) se ha convertido en el tratamiento más efectivo para la hipoacusia neurosensorial severa-profunda. En los últimos años se han ampliado sus indicaciones, especialmente los casos bilaterales. Es por ello que en la comunidad otológica surge el interrogante de cómo puede afectar a la función vestibular la inserción de un array de electrodos intracocleares. Material y

método:

Estudio descriptivo, de tipo longitudinal, entre diciembre de 2013 y julio de 2016. Se realizó una revisión de 92 historias clínicas de pacientes que se sometieron a implante coclear en el mismo centro por el mismo equipo y cumplían criterios de inclusión.

Resultados:

De los 92 pacientes evaluados en el preoperatorio se observaron Normofunción vestibular bilateral 56 pacientes (60,8%), Hipofunción vestibular bilateral 13 pacientes (14,1%), Hipofunción vestibular unilateral 21 pacientes (22,8%). De los 46 oídos evaluados pre y post IC, un 14,8% (7 pacientes) presentaron hipofunción vestibular post IC, con normofunción previa. Solo 2 pacientes del total de la muestra presentaron sintomatología vestibular severa, con hipovalencias objetivadas en el post operatorio.

Conclusiones:

Se recomienda evaluar la función vestibular periférica en todos los pacientes candidatos a implante coclear, ya que de no existir otras consideraciones podría ser de utilidad a la hora de definir el lado a implantar.
ABSTRACT

Introduction:

cochlear implant (IC) has become the most effective treatment for severe-deep neurosensory hearing loss. In recent years, indications have been extended, especially bilateral cases. This is why in the otological community the question arises as to how insertion of an array of intracochlear electrodes can affect the vestibular function. Material and

method:

A descriptive longitudinal study between december 2013 and july 2016. A review of 92 clinical records of patients who underwent cochlear implantation at the same center by the same team and met inclusion criteria were performed.

Results:

Of the 92 patients evaluated in the preoperative period, bilateral vestibular normobility 56 patients (60.8%), bilateral vestibular hypofunction 13 patients (14.1%), unilateral vestibular hypofunction 21 patients (22.8%). Of the 46 ears assessed pre- and post-IC, 14.8% (7 patients) presented vestibular hypofunction post-IC, with previous normofunction. Only 2 patients from the total sample had severe vestibular symptoms, with postoperative hypovalences.

Conclusions:

It is recommended to evaluate the peripheral vestibular function in all patients candidates for cochlear implants since, if there were no other considerations, it might be useful to define the side to be implanted.
RESUMO

Introdução:

el implante coclear (IC) se ha transformado no tratamento mais efectivo para a hipoacusia neurosensorial severa-profunda. Os últimos juros se han ampliado sus indicaciones, especialmente os casos bilaterais. É por isso que na comunidade otológica surge o interrogante de como pode afetar a função vestibular a inserção de uma matriz de eletrodos intracocleares. Material e

método:

Estudo descritivo, de tipo longitudinal, entre dezembro de 2013 e julho de 2016. Se realizou uma revisão de 92 historias clínicas de pacientes que se tornaram mais importantes um implante coclear em si mesmo por meio do mesmo e consideramos critérios de inclusão.

Resultados:

De los 92 pacientes avaliados no pré- operatório observado Normofunção vestibular bilateral 56 pacientes (60,8%), Hipofunção vestibular bilateral 13 pacientes (14,1%), Hipofunção vestibular unilateral 21 pacientes (22,8%). De los 46 oídos avaliados e pós IC, un 14,8% (7 pacientes) apresentaram hipofunção vestibular post IC, con normofunción previa. Solo 2 pacientes do total da amostra apresentaram sintomatologia vestibular severa, com hipovalencias objetivadas no pós-operatório.

Conclusões:

verificar a função vestibular periférica em todos os pacientes candidatos a implante coclear ya que não existe de outras formas consideradas poder ser de utilidade à hora de definir o lado a implantar.
Subject(s)

Full text: Available Index: LILACS (Americas) Main subject: Vestibular Function Tests Type of study: Diagnostic study / Observational study Limits: Female / Humans / Male Language: Spanish Journal: Rev. Fed. Argent. Soc. Otorrinolaringol Journal subject: Otolaringologia Year: 2017 Type: Article Affiliation country: Argentina Institution/Affiliation country: Instituto Superior de Otorrinolaringología/AR

Similar

MEDLINE

...
LILACS

LIS

Full text: Available Index: LILACS (Americas) Main subject: Vestibular Function Tests Type of study: Diagnostic study / Observational study Limits: Female / Humans / Male Language: Spanish Journal: Rev. Fed. Argent. Soc. Otorrinolaringol Journal subject: Otolaringologia Year: 2017 Type: Article Affiliation country: Argentina Institution/Affiliation country: Instituto Superior de Otorrinolaringología/AR