Your browser doesn't support javascript.
loading
Avaliação da qualidade microbiológica da água potável em Centro Universitário de Ribeirão Preto, SP / Evaluation of the microbiological quality of drinking water in Centro Universitário de Ribeirão Preto, SP
Ungari, Andrea Queiróz; Puga, Amanda Mendonça; Petracca, Giovana Labate.
  • Ungari, Andrea Queiróz; Centro Universitário Barão de Mauá. São Paulo. BR
  • Puga, Amanda Mendonça; Centro Universitário Barão de Mauá. São Paulo. BR
  • Petracca, Giovana Labate; Centro Universitário Barão de Mauá. São Paulo. BR
Hig. aliment ; 32(280/281): 47-51, 30/06/2018. tab, ilus
Article in Portuguese | LILACS | ID: biblio-910376
RESUMO
Avaliar a qualidade microbiológica da água potável consumida no Centro Universitário Barão de Mauá, em Ribeirão Preto-SP foi o objetivo deste artigo. Para determinação de bactérias heterotróficas foi realizada a técnica de Pour Plate e a identificação de Coliformes totais e termotolerantes por meio do reagente substrato cromogênico Colilert®. As análises foram realizadas nos dias 18 e 25 de setembro e 02 de outubro de 2017. Dos sete pontos analisados, um bebedouro apresentou valores de bactérias heterotróficas, superiores a 500 UFC/mL e não está de acordo com a Portaria nº 2914/2011, que dispõe sobre os procedimentos de controle e de vigilância da qualidade da água para consumo humano e seu padrão de potabilidade. As análises de Coliformes totais e termotolerantes apresentaram resultados ausentes em 100 mL de acordo com a Portaria. Este estudo reforça a necessidade de um constante monitoramento da qualidade microbiológica da água, visando os padrões adequados de potabilidade para consumo humano e então, prevenindo-se possíveis doenças.
ABSTRACT
Evaluating the microbiological quality of drinking water consumed at the Centro Universitário Barão de Mauá, in Ribeirão Preto, SP was the objective of this article. The determination of heterotrophic bacteria was carried out using the "Pour Plate" technique and the identification of total and thermotolerant Coliforms through the Colilert® chromogenic substrate reagent. The analyzes were carried out on September 18 and 25 and October 2, 2017. Of the seven points analyzed points analyzed, a drinking fountain had heterotrophic bacteria values higher than 500 CFU/ mL of heterotrophic bacteria and is not in accordance with Administrative Rule 2914/2011, which provides on the procedures for controlling and monitoring the quality of water for human consumption and its drinking water standard. The analyzes of total and thermotolerant Coliforms presented absent results in 100 mL according to the Ordinance. This study reinforces the need for a constant monitoring of the microbiological quality of the water, aiming at the appropriate standards of potability for human consumption and then, preventing possible diseases.
Subject(s)

Full text: Available Index: LILACS (Americas) Main subject: Drinking Water / Coliforms / Heterotrophic Bacteria Type of study: Practice guideline Language: Portuguese Journal: Hig. aliment Journal subject: Nutritional Sciences Year: 2018 Type: Article Affiliation country: Brazil Institution/Affiliation country: Centro Universitário Barão de Mauá/BR

Similar

MEDLINE

...
LILACS

LIS

Full text: Available Index: LILACS (Americas) Main subject: Drinking Water / Coliforms / Heterotrophic Bacteria Type of study: Practice guideline Language: Portuguese Journal: Hig. aliment Journal subject: Nutritional Sciences Year: 2018 Type: Article Affiliation country: Brazil Institution/Affiliation country: Centro Universitário Barão de Mauá/BR