Your browser doesn't support javascript.
loading
Comparación del algoritmo nuevo con el algoritmo convencional para diagnóstico de VIH en Bolivia / Comparison of new algorithm with the conventional algorithm for diagnosis of HIV in Bolivia / Comparação do novo algoritmo com o algoritmo convencional para o diagnóstico do HIV na Bolívia
Martínez-Oliva, Brenda Gisela; Montaño-Valenzuela, Karen Jimena; Rodriguez-Herbas, Patricia; Flores-León, Amilcar Alejandr; Grados-Torrez, Ricardo Enrique.
  • Martínez-Oliva, Brenda Gisela; Universidad Mayor de San Simón. Facultad de Medicina. Laboratorio de Virología - LABIMED. Cochabamba. BO
  • Montaño-Valenzuela, Karen Jimena; Universidad Mayor de San Simón. Facultad de Medicina. Laboratorio de Virología - LABIMED. Cochabamba. BO
  • Rodriguez-Herbas, Patricia; Universidad Mayor de San Simón. Facultad de Medicina. Laboratorio de Virología - LABIMED. Cochabamba. BO
  • Flores-León, Amilcar Alejandr; Universidad Mayor de San Simón. Facultad de Medicina. Laboratorio de Virología - LABIMED. Cochabamba. BO
  • Grados-Torrez, Ricardo Enrique; Universidad Mayor de San Andrés. Instituto de Investigaciones Fármaco Bioquímicas (I.I.F.B.) Luis Enrique Terrazas Siles. Laboratorio de Farmacología. La Paz. BO
Acta bioquím. clín. latinoam ; 52(2): 227-234, jun. 2018. ilus, tab
Article in Spanish | LILACS | ID: biblio-949336
RESUMEN
En Bolivia, el algoritmo diagnóstico convencional para VIH utiliza como prueba confirmatoria el Western blot; debido a dificultades con el costo, tiempo y centralización del diagnóstico confirmatorio, el Programa Nacional ITS/VIH/SIDA-HV propuso un algoritmo nuevo que utiliza solo dos pruebas rápidas y ELISA Ag/Ac. Sesenta muestras de suero fueron procesadas con ambos algoritmos y se determinó el resultado verdadero de las muestras de acuerdo con ambos algoritmos y la carga viral. La sensibilidad, especificidad, valores predictivos, índice Kappa y chi-cuadrado de Pearson fueron calculados. El algoritmo convencional reportó: sensibilidad 96,3%, especificidad 100%, valor predictivo positivo 100% y valor predictivo negativo 97% el algoritmo nuevo presentó sensibilidad, especificidad, valores predictivos positivo y negativo del 100%. El índice Kappa fue 0,966 y chi-cuadrado de Pearson 56,078 con p<0,01; es así que el grado de concordancia entre ambos algoritmos es "muy bueno" y estadísticamente significativo. Aunque el número de muestras procesadas en este estudio fue reducido, el algoritmo nuevo parece ser mejor que el convencional debido a que acorta el tiempo de detección de VIH y reporta resultados iguales a la carga viral.
ABSTRACT
In Bolivia, the conventional diagnostic algorithm for HIV uses Western blot as a confirmatory test. Due to difficulties with cost, time and centralization of the confirmatory diagnosis, the National STI/HIV/AIDS-HV Program proposed a new algorithm, which uses only two rapid tests and ELISA Ag/Ac. A total of 60 serum samples were processed with both algorithms and the true result of the samples was determined according to the results of both algorithms and viral load. Sensitivity, specificity, predictive values, Kappa and chi-square Pearson index were determined. The conventional algorithm reported sensitivity of 96,3%, specificity of 100%, positive predictive value of 100 % and negative predictive value of 97%. The new algorithm presented sensitivity, specificity, positive and negative predictive values of 100%. The Kappa index was 0.966 and chi-square Pearson 56.078 with p <0.01, so the degree of agreement between both algorithms is "very good" and statistically significant. Although the number of samples processed in the present work was reduced, the new algorithm seems to be better than the conventional algorithm because it shortens the period in the detection of HIV and reports results equal to the viral load.
RESUMO
Na Bolívia, o algoritmo de diagnóstico convencional para HIV usa como teste de confirmação o Western blot; devido a dificuldades com custo, tempo e centralização do diagnóstico de confirmação, o Programa Nacional de ITS/HIV/AIDS-HV propôs um algoritmo que usa apenas dois testes rápidos e ELISA Ag/Ac. Foram processadas 60 amostras de soro com ambos os algoritmos e o resultado verdadeiro das amostras foi determinado de acordo com os algoritmos e a carga viral. A sensibilidade, especificidade, valores preditivos, índice de Kappa e qui-quadrado de Pearson foram calculados. O algoritmo convencional reportou: sensibilidade 96,3%, especificidade 100%, valor preditivo positivo 100% e valor preditivo negativo 97%, o novo algoritmo apresentou sensibilidade, especificidade, valores preditivos positivo e negativo de 100%. O índice Kappa foi 0.966 e qui-quadrado de Pearson 56.078 com p<0.01, de modo que o grau de concordância entre os algoritmos é "muito bom" e estatisticamente significativo. Embora o número de amostras processadas neste estudo tenha sido pequeno, o novo algoritmo parece ser melhor do que o convencional porque reduz o tempo de detecção do HIV e relata resultados iguais à carga viral.
Subject(s)

Full text: Available Index: LILACS (Americas) Main subject: Blotting, Western / Viral Load / HIV Testing Type of study: Diagnostic study / Prognostic study Country/Region as subject: South America / Bolivia Language: Spanish Journal: Acta bioquím. clín. latinoam Journal subject: Bioqu¡mica / Qu¡mica Cl¡nica Year: 2018 Type: Article Affiliation country: Bolivia Institution/Affiliation country: Universidad Mayor de San Andrés/BO / Universidad Mayor de San Simón/BO

Similar

MEDLINE

...
LILACS

LIS

Full text: Available Index: LILACS (Americas) Main subject: Blotting, Western / Viral Load / HIV Testing Type of study: Diagnostic study / Prognostic study Country/Region as subject: South America / Bolivia Language: Spanish Journal: Acta bioquím. clín. latinoam Journal subject: Bioqu¡mica / Qu¡mica Cl¡nica Year: 2018 Type: Article Affiliation country: Bolivia Institution/Affiliation country: Universidad Mayor de San Andrés/BO / Universidad Mayor de San Simón/BO