Your browser doesn't support javascript.
loading
Comparación de dos piezas bucales en la medición de PImáx y PEmáx en sujetos adultos / Comparison of two mouthpieces in the measurement of MIP and MEP in adults
Herrero, María Victoria; Faggionato, Martina; Cigarra, Cecilia Mariela; Rigoni, María Luz; de la Cruz, Mariano Agustín; Díaz Ballvé, Pablo.
  • Herrero, María Victoria; Hospital Petrona Villegas de Cordero. San Fernando. AR
  • Faggionato, Martina; Hospital Petrona Villegas de Cordero. San Fernando. AR
  • Cigarra, Cecilia Mariela; Hospital Petrona Villegas de Cordero. San Fernando. AR
  • Rigoni, María Luz; Hospital Petrona Villegas de Cordero. San Fernando. AR
  • de la Cruz, Mariano Agustín; Hospital Petrona Villegas de Cordero. San Fernando. AR
  • Díaz Ballvé, Pablo; Hospital Profesor Alejandro Posadas. El Palomar. AR
Rev. am. med. respir ; 18(2): 89-99, jun. 2018. ilus, graf, tab
Article in Spanish | LILACS | ID: biblio-957570
RESUMEN

Objetivos:

Comparar y establecer el grado de acuerdo entre los valores de Presión Inspiratoria máxima (PImáx) y Presión Espiratoria máxima (PEmáx) medidos con pipeta bucal y boquilla de buceo, en adultos. El objetivo secundario fue evaluar el grado de acuerdo entre los valores calculados con las ecuaciones de Evans y Whitelaw y los valores máximos obtenidos con cada interfaz. Materiales y

método:

Se llevó a cabo un estudio observacional, descriptivo, prospectivo y transversal. Se realizó un muestreo consecutivo no probabilístico de sujetos argentinos entre 18 y 69 años de edad. Se midieron PImáx y PEmáx utilizando un sistema de válvulas unidireccionales y un manovacuómetro aneroide, con boquilla de buceo y pipeta bucal.

Resultados:

Se incluyeron 240 sujetos que completaron la totalidad de las mediciones con ambas interfaces. Los valores de PEmáx con pipeta bucal fueron mayores que los obtenidos con boquilla de buceo (p < 0.01), con un Coeficiente de Correlación Intraclase (ICC sigla en inglés) entre ambas de 0.80 (IC 95% 0.74-0.84). Para PImáx no hubo diferencias entre ambas interfaces, con un ICC de 0.88 (IC 95% 0.85-0.91). Los ICC para las ecuaciones de Evans y Whitelaw y los máximos valores alcanzados por los sujetos fueron de -0.15 a 0.09 mostraron un grado de acuerdo pobre.

Conclusión:

Los valores de PEmáx con pipeta bucal fueron mayores que los obtenidos con la boquilla de buceo. No se detectaron diferencias entre ambas interfaces para PImáx. En la población estudiada las fórmulas de Evans y Whitelaw no fueron exitosas en la predicción de presiones máximas.
ABSTRACT

Objectives:

To compare and establish the degree of agreement between the values of Maximal Inspiratory Pressure (MIP) and Maximal Expiratory Pressure (MEP) measured with a plastic mouthpiece and a scuba type mouthpiece in adults. The secondary objective was to evaluate the degree of agreement between the values calculated with Evans and Whitelaw equation and the maximal values attained with each mouthpiece.

Methods:

We conducted an analytical observational transversal study. Sampling was non-probabilistic, of Argentinian subjects aged between 18 and 69 years old. We measured MIP and MEP with an unidirectional valves system and an aneroid manovacuometer, with a plastic mouthpiece and a scuba type mouthpiece.

Results:

240 subjects were included and completed all the measurements with both mouthpieces. MEP values were higher when measured with a plastic mouthpiece than with the scuba type (p < 0.01), with an Intraclass Correlation Coefficient (ICC) between both of 0.80 (CI 95% 0.74-0.84). There were no differences in MIP between both mouthpieces, with an ICC of 0.88 (CI 95% 0.85-0.91). The ICC between Evans and Whitelaw predictive values and the maximal values attained by the subjects varied from -0.15 to 0.09, showing a poor degree of agreement.

Conclusion:

MEP values attained with a plastic mouthpiece are greater than those attained with a scuba type mouthpiece. There are no differences between both mouthpieces for MIP. Evans and Whitelaw equations are not successful in predicting maximal pressures in the population here studied.
Subject(s)

Full text: Available Index: LILACS (Americas) Main subject: Respiratory Muscles / Maximal Respiratory Pressures Type of study: Observational study / Prevalence study Language: Spanish Journal: Rev. am. med. respir Journal subject: Medicine / Pulmonary Disease (Specialty) Year: 2018 Type: Article Affiliation country: Argentina Institution/Affiliation country: Hospital Petrona Villegas de Cordero/AR / Hospital Profesor Alejandro Posadas/AR

Similar

MEDLINE

...
LILACS

LIS

Full text: Available Index: LILACS (Americas) Main subject: Respiratory Muscles / Maximal Respiratory Pressures Type of study: Observational study / Prevalence study Language: Spanish Journal: Rev. am. med. respir Journal subject: Medicine / Pulmonary Disease (Specialty) Year: 2018 Type: Article Affiliation country: Argentina Institution/Affiliation country: Hospital Petrona Villegas de Cordero/AR / Hospital Profesor Alejandro Posadas/AR