Your browser doesn't support javascript.
loading
Efecto del sistema de recuperación de sangre autóloga y transfusiones homólogas en pacientes quirúrgicos de alta complejidad / Effect of homologous transfusions and the autologous blood recovery system in highly complex surgical patients
Delgado Rivas, Jennifer; Echanique, Patricio; Plaza Cepeda, Jorge.
  • Delgado Rivas, Jennifer; Hospital Alcívar. Guayaquil. EC
  • Echanique, Patricio; Hospital Alcívar. Guayaquil. EC
  • Plaza Cepeda, Jorge; Hospital Alcívar. Guayaquil. EC
Rev. cuba. anestesiol. reanim ; 16(3): 1-10, set.-dic. 2017. ilus, tab
Article in Spanish | LILACS, CUMED | ID: biblio-960313
RESUMEN

Introducción:

la transfusión autóloga presenta tres modalidades transfusión autóloga con predepósito, hemodilución preoperatoria (normovolémica o hipervolémica) y el sistema de recuperación de sangre autóloga (cell saver) intraoperatoria o posoperatoria.

Objetivo:

demostrar la efectividad del uso del sistema de recuperación de sangre autóloga en pacientes quirúrgicos de alta complejidad en el Hospital Alcívar.

Método:

estudio retrospectivo, no experimental, de observación indirecta, con análisis correlacional. La muestra fue de 112 pacientes intervenidos por afecciones cardiovasculares, ortopédicas y traumatológicas, incluidos según criterios de inclusión y exclusión. Se utilizó cell saver en 56 pacientes, y 56 pacientes utilizaron transfusiones de sangre homóloga. Resultados. el cell saver fue beneficioso en 93 por ciento de los pacientes; la morbilidad y la mortalidad disminuyeron, principalmente en los pacientes intervenidos de cualquier afección cardiovascular y aumentó el índice costo/beneficio, debido a que se priorizaron los recursos económicos. En traumatología y ortopedia no fue muy beneficioso, pues la cantidad de sangre recuperada fluctuó entre 300 y 500 mL en intervenciones convencionales, lo que motivó el uso de hemoderivados y aumentó el costo. En resecciones tumorales e instrumentaciones en diferentes segmentos de la columna vertebral se recuperó hasta 800 mL de sangre, lo que resultó significativo. La tasa de complicaciones fue menor en pacientes que utilizaron cell saver (7 por ciento) frente a los pacientes que utilizaron hemoderivados homólogos (32 por ciento). Se constató una menor estancia hospitalaria en el grupo cell saver (1-20 días) en comparación con los que usaron hemoderivados homólogos (> 10 días, en 5 casos fue mayor 21 días).

Conclusiones:

el uso de sistema de recuperación de sangre autóloga constituye un procedimiento efectivo para infundir hemoderivados con mayor seguridad(AU)
ABSTRACT

Introduction:

Autologous transfusion has three modalities autologous transfusion with predeposit, preoperative hemodilution (normovolemic or hypervolemic), and the system for autologous blood recovery (cell saver), whether intraoperative or postoperative.

Objective:

To show the effectiveness of the use of the autologous blood recovery system in highly complex surgical patients at Alcívar Hospital.

Method:

Nonexperimental, retrospective study, of indirect observation and with correlational analysis. The sample consisted of 112 patients who underwent surgery for cardiovascular, orthopedic and traumatological conditions, chosen based on inclusion and exclusion criteria. The cell saver system was used in 56 patients and 56 patients used homologous blood transfusions.

Results:

The cell saver system was beneficial in 93 percent of patients; morbidity and mortality decreased, mainly in patients operated for any cardiovascular condition, while the cost-benefit ratio increased, due to the fact prioritization of economic resources. In traumatology and orthopedics, it was not so beneficial, since the amount of blood recovered fluctuated between 300 and 500 mL in conventional interventions, which motivated the use of blood products and increased the cost. In tumor resections and instrumentation of different spine segments, up to 800 mL of blood were recovered, which was significant. The complication rate was lower in patients who used the cell saver system (7 percent), compared to patients who used homologous blood products (32 percent). A shorter hospital stay was observed in the cell saver group (1-20 days), compared to those who used homologous blood products (over 10 days, while in 5 cases it was over 21 days).

Conclusions:

The use of the autologous blood recovery system is an effective procedure to infuse blood products with greater safety(AU)
Subject(s)

Full text: Available Index: LILACS (Americas) Main subject: Surgical Procedures, Operative / Blood Transfusion, Autologous / Operative Blood Salvage Type of study: Observational study Limits: Humans Language: Spanish Journal: Rev. cuba. anestesiol. reanim Journal subject: Anesthesiology Year: 2017 Type: Article Affiliation country: Ecuador Institution/Affiliation country: Hospital Alcívar/EC

Similar

MEDLINE

...
LILACS

LIS

Full text: Available Index: LILACS (Americas) Main subject: Surgical Procedures, Operative / Blood Transfusion, Autologous / Operative Blood Salvage Type of study: Observational study Limits: Humans Language: Spanish Journal: Rev. cuba. anestesiol. reanim Journal subject: Anesthesiology Year: 2017 Type: Article Affiliation country: Ecuador Institution/Affiliation country: Hospital Alcívar/EC