Your browser doesn't support javascript.
loading
Forced degradation of gliquidone and development of validated stability-indicating HPLC and TLC methods
El-ghobashy, Mohamed Refaat; Yehia, Ali Mohamed; Helmy, Aya Helmy; Youssef, Nadia Fayek.
  • El-ghobashy, Mohamed Refaat; Cairo University. Analytical Chemistry Department. Faculty of Pharmacy. Cairo. EG
  • Yehia, Ali Mohamed; Cairo University. Analytical Chemistry Department. Faculty of Pharmacy. Cairo. EG
  • Helmy, Aya Helmy; National Organization for Drug Control and Research. Pharmaceutical Chemistry Department. Giza. EG
  • Youssef, Nadia Fayek; National Organization for Drug Control and Research. Pharmaceutical Chemistry Department. Giza. EG
Braz. J. Pharm. Sci. (Online) ; 54(3): e00223, 2018. tab, graf
Article in English | LILACS | ID: biblio-974412
ABSTRACT
Forced degradation studies of gliquidone were conducted under different stress conditions. Three degradates were observed upon using HPLC and TLC and elucidated by LC-MS and IR. HPLC method was performed on C18 column using methanol-water (8515 v/v) pH 3.5 as a mobile phase with isocratic mode at 1 mL.min-1 and detection at 225 nm. HPLC analysis was applied in range of 0.5-20 µg.mL-1 (r =1) with limit of detection (LOD) 0.177 µg.mL-1. TLC method was based on the separation of gliquidone from degradation products on silica gel TLC F254 plates using chloroform-cyclohexane-glacial acetic acid (631v/v) as a developing system with relative retardation 1.15±0.01. Densitometric measurements were achieved in range of 2 -20 µg /band at 254 nm (r = 0.9999) with LOD of 0.26 µg /band. Least squares regression analysis was applied to provide mathematical estimates of the degree of linearity. The analysis revealed a linear calibration for HPLC where a binomial relationship for TLC. Stability testing and methods validation have been evaluated according to International Conference on Harmonization guidelines. Moreover, the proposed methods were applied for the analysis of tablets and the results obtained were statistically compared with those of pharmacopeial method revealing no significant difference about accuracy and precision.
Subject(s)


Full text: Available Index: LILACS (Americas) Main subject: Chromatography, High Pressure Liquid / Hypoglycemic Agents Language: English Journal: Braz. J. Pharm. Sci. (Online) Journal subject: Farmacologia / Terapˆutica / Toxicologia Year: 2018 Type: Article Affiliation country: Egypt Institution/Affiliation country: Cairo University/EG / National Organization for Drug Control and Research/EG

Similar

MEDLINE

...
LILACS

LIS


Full text: Available Index: LILACS (Americas) Main subject: Chromatography, High Pressure Liquid / Hypoglycemic Agents Language: English Journal: Braz. J. Pharm. Sci. (Online) Journal subject: Farmacologia / Terapˆutica / Toxicologia Year: 2018 Type: Article Affiliation country: Egypt Institution/Affiliation country: Cairo University/EG / National Organization for Drug Control and Research/EG