Your browser doesn't support javascript.
loading
Hydrodynamic evaluations of four mock femoral venous cannulas
Sahin, Türker; Tezer, Murat; Cerit, Levent.
  • Sahin, Türker; Near East University. Department of Cardiovascular Surgery. Nicosia. CY
  • Tezer, Murat; Near East University. Faculty of Educational Science. Nicosia. CY
  • Cerit, Levent; Near East University. Department of Cardiology. Nicosia. CY
Rev. bras. cir. cardiovasc ; 33(5): 435-442, Sept.-Oct. 2018. tab, graf
Article in English | LILACS | ID: biblio-977452
ABSTRACT
Abstract

Objective:

To report the results of four mock femoral venous cannulas and the hydrodynamical superiority of one of them, which is the completely punched (CP) model, upon the other three.

Methods:

Four simulated femoral venous cannulas (single-stage, two-stage, multi-stage, and CP model) were designed from a 1/4" x 1/16" x 68 cm polyvinyl chloride (PVC) tubing line for testing. Holes on the PVC tubes were opened by a 5 mm aortic punch. In order to evaluate the cannulas' drainage performance, gelofusine was used as fluid. The fluid was drained for 60 seconds by gravitation and then measured for each model separately.

Results:

Mean drained volumes of single-stage, two-stage, and multi-stage cannulas were 2.483, 2.561, and 2.603 mL, respectively. However, the CP cannula provided us a mean drained volume of 2.988 mL. There were significant differences among the variables of the CP cannula and the other three mock cannulas concerning the drained fluid flow (P<0.01).

Conclusion:

In our study, the measured mean volumes showed us that more drainage surface area provides better fluid drainage.
Subject(s)


Full text: Available Index: LILACS (Americas) Main subject: Blood Flow Velocity / Materials Testing / Catheterization / Cardiopulmonary Bypass / Equipment Design / Cannula Type of study: Prognostic study Language: English Journal: Rev. bras. cir. cardiovasc Journal subject: Cardiology / General Surgery Year: 2018 Type: Article Affiliation country: Cyprus Institution/Affiliation country: Near East University/CY

Similar

MEDLINE

...
LILACS

LIS


Full text: Available Index: LILACS (Americas) Main subject: Blood Flow Velocity / Materials Testing / Catheterization / Cardiopulmonary Bypass / Equipment Design / Cannula Type of study: Prognostic study Language: English Journal: Rev. bras. cir. cardiovasc Journal subject: Cardiology / General Surgery Year: 2018 Type: Article Affiliation country: Cyprus Institution/Affiliation country: Near East University/CY