Your browser doesn't support javascript.
loading
Factores de riesgo para fracaso en la extubación en la unidad de cuidados intensivos / Risk factors for extubation failure in the intensive care unit
Silva-Cruz, Aracely Lizet; Velarde-Jacay, Karina; Carreazo, Nilton Yhuri; Escalante-Kanashiro, Raffo.
  • Silva-Cruz, Aracely Lizet; Universidad Peruana de Ciencias Aplicadas. Facultad de Ciencias de la Salud. Lima. PE
  • Velarde-Jacay, Karina; Universidad Peruana de Ciencias Aplicadas. Facultad de Ciencias de la Salud. Lima. PE
  • Carreazo, Nilton Yhuri; Universidad Peruana de Ciencias Aplicadas. Facultad de Ciencias de la Salud. Lima. PE
  • Escalante-Kanashiro, Raffo; Universidad Peruana de Ciencias Aplicadas. Facultad de Ciencias de la Salud. Lima. PE
Rev. bras. ter. intensiva ; 30(3): 294-300, jul.-set. 2018. tab, graf
Article in Spanish | LILACS | ID: biblio-977965
RESUMEN
RESUMEN

Objetivo:

Determinar los factores de riesgo para fracaso en la extubación en la unidad de cuidados intensivos.

Métodos:

El presente estudio de casos y controles se llevó a cabo en la unidad de cuidados intensivos. Se tomó como casos a las extubaciones fallidas y como controles a las extubaciones exitosas. El fracaso de la extubación se definió como la reintubación dentro de las primeras 48 horas.

Resultados:

De un total de 956 pacientes que fueron admitidos en la unidad de cuidados intensivos, 826 fueron sometidos a ventilación mecánica (86%). Se presentaron 30 extubaciones fallidas y 120 extubaciones exitosas. La proporción de extubaciones fallidas fue de 5,32%. Los factores de riesgo encontrados para extubaciones fallidas fueron la estancia prolongada de ventilación mecánica mayor a 7 días (OR = 3,84; IC95% = 1,01 - 14,56; p = 0,04), el tiempo en unidad de cuidados intensivos (OR = 1,04; IC95% = 1,00 - 1,09; p = 0,03) y el uso de sedantes mayor a 5 días (OR = 4,81; IC95% = 1,28 - 18,02; p = 0,02).

Conclusión:

Los pacientes pediátricos en ventilación mecánica tienen más riesgo de presentar extubaciones fallidas si permanecen mayor tiempo en unidad de cuidados intensivos, si están sometidos a tiempo prolongado de ventilación mecánica mayor de 7 días y al uso de sedantes.
ABSTRACT
ABSTRACT

Objective:

To determine the risk factors for extubation failure in the intensive care unit.

Methods:

The present case-control study was conducted in an intensive care unit. Failed extubations were used as cases, while successful extubations were used as controls. Extubation failure was defined as reintubation being required within the first 48 hours of extubation.

Results:

Out of a total of 956 patients who were admitted to the intensive care unit, 826 were subjected to mechanical ventilation (86%). There were 30 failed extubations and 120 successful extubations. The proportion of failed extubations was 5.32%. The risk factors found for failed extubations were a prolonged length of mechanical ventilation of greater than 7 days (OR = 3.84, 95%CI = 1.01 - 14.56, p = 0.04), time in the intensive care unit (OR = 1.04, 95%CI = 1.00 - 1.09, p = 0.03) and the use of sedatives for longer than 5 days (OR = 4.81, 95%CI = 1.28 - 18.02; p = 0.02).

Conclusion:

Pediatric patients on mechanical ventilation were at greater risk of failed extubation if they spent more time in the intensive care unit and if they were subjected to prolonged mechanical ventilation (longer than 7 days) or greater amounts of sedative use.
Subject(s)


Full text: Available Index: LILACS (Americas) Main subject: Respiration, Artificial / Ventilator Weaning / Airway Extubation / Intubation, Intratracheal Type of study: Etiology study / Observational study / Risk factors Limits: Child / Child, preschool / Female / Humans / Infant / Male Language: Spanish Journal: Rev. bras. ter. intensiva Journal subject: Critical Care Year: 2018 Type: Article Affiliation country: Peru Institution/Affiliation country: Universidad Peruana de Ciencias Aplicadas/PE

Similar

MEDLINE

...
LILACS

LIS


Full text: Available Index: LILACS (Americas) Main subject: Respiration, Artificial / Ventilator Weaning / Airway Extubation / Intubation, Intratracheal Type of study: Etiology study / Observational study / Risk factors Limits: Child / Child, preschool / Female / Humans / Infant / Male Language: Spanish Journal: Rev. bras. ter. intensiva Journal subject: Critical Care Year: 2018 Type: Article Affiliation country: Peru Institution/Affiliation country: Universidad Peruana de Ciencias Aplicadas/PE