Aplicación clínica de la técnica 4D Flow en la evaluación hemodinámica de cardiopatías congénitas / Clinical Applications of 4D Flow in the Hemodynamic Evaluation of Congenital Heart Diseases
Pineda, Julián; Abad, Pedro; Mesa, Sara; Rascovsky, Simón; Delgado, Jorge.
  • Pineda, Julián; Instituto de Alta Tecnología Médica. CO
  • Abad, Pedro; Instituto de Alta Tecnología Médica (IATM). CO
  • Mesa, Sara; Instituto de Alta Tecnología Médica (IATM). CO
  • Rascovsky, Simón; Instituto de Alta Tecnología Médica (IATM). CO
  • Delgado, Jorge; Clínica SOMA. CO
Rev. colomb. radiol ; 29(2): 4901-4907, 2018. llus, graf
Article in Spanish | LILACS | ID: biblio-986288
RESUMEN
La técnica 4D Flow hace referencia a las imágenes de resonancia magnética (RM) adquiridas mediante una secuencia retrospectiva de angiografía contraste de fase, en la cual se obtienen datos de la velocidad de la sangre en las tres direcciones, en un espacio de 3 dimensiones (3D) y a través de todo el ciclo cardiaco. Con las imágenes obtenidas mediante 4D Flow se puede evaluar de forma cuantitativa la dinámica regional y global del flujo sanguíneo con medidas hemodinámicas, tales como velocidad promedio, máxima y mínima, flujo latido promedio, flujo de avance y regurgitante, volumen de eyección, y aproximaciones matemáticas a los gradientes de presión y fuerzas de cizallamiento en las paredes de los vasos; además, permite analizar cualitativamente la evolución temporal de los complejos patrones de flujo sanguíneo por medio de líneas de flujo, trazadores de partículas, gráficas de velocidad 3D y vectores; representaciones que describen la trayectoria de la sangre, a través del tiempo, en el sistema cardiovascular. Estas características permiten que la técnica tenga muchas aplicaciones potenciales en la práctica clínica, ya que brindan al especialista información valiosa sobre la función y el estado del sistema cardiovascular del paciente. A continuación se evalúa mediante 4D Flow, en algunas patologías congénitas estenosis valvular pulmonar, conducto arterioso persistente y estenosis aórtica.
ABSTRACT
4D Flow technique refers to MR images acquired through a phase contrast angiography retrospective sequence, in which blood velocity data are obtained in three directions, in a 3-dimensional space, and through all of the cardiac cycle. With the 4D flow images, the regional and global dynamics of blood flow can be quantitatively analyzed through hemodynamic measurements, such as average, maximum and minimum velocity, average flow, forward and regurgitation flow, ejection volume, and mathematical approximations to pressure gradients and shear forces in vessel walls; It also allows analyze qualitatively the temporal evolution of complex blood flow patterns through flow lines, particle tracers, 3D velocity graphs and vectors; representations that describe the trajectory of the blood, over time, in the cardiovascular system. These characteristics make the technique have many potential applications in clinical practice, as it provides information on the function and status of the patient's cardiovascular system. In this study we evaluated with the 4D flow technique some congenital pathologies pulmonary stenosis, patent ductus arteriosus, and aortic stenosis.
Subject(s)

Full text: Available Index: LILACS (Americas) Main subject: Magnetic Resonance Imaging Language: Spanish Journal: Rev. colomb. radiol Journal subject: Radiology Year: 2018 Type: Article Affiliation country: Colombia Institution/Affiliation country: Clínica SOMA/CO / Instituto de Alta Tecnología Médica (IATM)/CO / Instituto de Alta Tecnología Médica/CO

Similar

MEDLINE

...
LILACS

LIS

Full text: Available Index: LILACS (Americas) Main subject: Magnetic Resonance Imaging Language: Spanish Journal: Rev. colomb. radiol Journal subject: Radiology Year: 2018 Type: Article Affiliation country: Colombia Institution/Affiliation country: Clínica SOMA/CO / Instituto de Alta Tecnología Médica (IATM)/CO / Instituto de Alta Tecnología Médica/CO