Your browser doesn't support javascript.
loading
Restauração classe II com resina composta: avaliação da técnica de Pollack / Restoration class II with composite resin: evaluation of the Pollack technique
Signor, Laryssa; Dullius, Angela isabel; Biacchi, Gislaine Rosa.
  • Signor, Laryssa; Universidade Federal de Santa Maria. Santa Maria. BR
  • Dullius, Angela isabel; Universidade Federal de Santa Maria. Santa Maria. BR
  • Biacchi, Gislaine Rosa; Universidade Federal de Santa Maria. Departamento de Odontologia Restauradora na área de Materiais Dentários. Santa Maria. BR
Odonto (Säo Bernardo do Campo) ; 25(49): 1-8, jan.-jun. 2017. ilus, tab
Article in Portuguese | LILACS, BBO | ID: biblio-996266
RESUMO
Apesar do notável aumento de restaurações posteriores com resinas compostas nos últimos anos, ainda existem dificuldades quanto à técnica restauradora em se tratando de cavidades com envolvimento da face proximal. Considera-se que a intensidade de luz que atinge os incrementos da resina na face cervical do preparo é menor do que a intensidade próxima à superfície, podendo comprometer as propriedades mecânicas e o sucesso da restauração.

Objetivo:

Investigar a resistência compressiva dos incrementos de resina composta de uso direto na profundidade da caixa proximal de restaurações classe II em diferentes extensões ocluso-cervicais utilizando- se a técnica incremental proposta por Pollack (1988).

Métodos:

Foram obtidos 40 espécimes (blocos) de resina composta, com 2 mm de dimensão ocluso-cervical, confeccionados a partir de restaurações classe II em três molares inferiores de manequim (Prodens) com dimensões de 4 mm vestíbulo-lingual, 2 mm mésio-distal e profundidades ocluso-cervical de 2 mm (G1 e G2), 4 mm (G3) e 6 mm (G4), formando 4 grupos (n=10). Para G1 (grupo controle) foi utilizada a resina autoativada (Alpha Plast) e demais grupos resina fotoativada (Z100, 3M ESPE), todos com espessura de 2mm. Após, os espécimes foram armazenados em soro fisiológico durante 30 dias e, posteriormente,submetidos ao teste de resistência à compressão em máquina universal de ensaios EMIC DL-2000, composta por um dispositivo metálico de base plana de 15mm, com célula de carga de 490N e velocidade de 0,5mm/min, aplicada sobre a face oclusal dos espécimes até a fratura.Os resultados foram analisados pelo teste ANOVA.

Resultados:

A média dos valores de resistência à fratura (MPa), foram 52,86; 48,55; 44,89; 42,67 para G1, G2, G3 e G4, respectivamente.

Conclusão:

Não houve diferença significativa (p>0,05) na resistência à compressão entre incrementos de resina composta inseridas na base da face proximal de preparos do tipo classe II em diferentes profundidades utilizando-se o protocolo adotado.(AU)
ABSTRACT
In spite of the remarkable increase of posterior restorations with composite resins in the last years, there are still difficulties regarding the restorative technique when dealing with cavities with involvement of the proximal face. It is considered that the light intensity that reaches the resin increments in the cervical face of the preparation is smaller than the intensity close to the surface, which may compromise the mechanical properties and the success of the restoration.

Objective:

To investigate the compressive strength of the composite resin increments of direct use in the depth of the proximal box of class II restorations in different occlusalcervical extensions using the incremental technique proposed by Pollack (1988).

Methods:

40 composite resin specimens with 2 mm occlusal-cervical dimensions were made from class II restorations in three lower molars of the manikin (Prodens) with 4 mm vestibullary, 2 mm mesio- Distal and occlusal-cervical depths of 2 mm (G1 and G2), 4 mm (G3) and 6 mm (G4), forming 4 groups (n = 10). For G1 (control group) the autoactivated resin (Alpha Plast) and other photoactivated resin groups (Z100, 3M ESPE) were used, all with a thickness of 2mm. Afterwards, the specimens were stored in saline solution for 30 days and then submitted to the compressive strength test in a universal EMIC DL-2000 test machine, consisting of a 15mm flat base metal device with a 490N load cell And velocity of 0.5 mm / min, applied on the occlusal face of the specimens until the fracture.The results were analyzed by the ANOVA test.

Results:

The average values of fracture resistance (MPa) were 52.86; 48.55; 44.89; 42.67 for G1, G2, G3 and G4, respectively.

Conclusion:

There was no significant difference (p> 0.05) in the compressive strength between increments of composite resin inserted at the base of the proximal face of class II type preparations at different depths using the protocol adopted.(AU)
Subject(s)


Full text: Available Index: LILACS (Americas) Main subject: Composite Resins / Dental Restoration, Permanent Type of study: Evaluation studies Language: Portuguese Journal: Odonto (Säo Bernardo do Campo) Journal subject: Dentistry Year: 2017 Type: Article Affiliation country: Brazil Institution/Affiliation country: Universidade Federal de Santa Maria/BR

Similar

MEDLINE

...
LILACS

LIS


Full text: Available Index: LILACS (Americas) Main subject: Composite Resins / Dental Restoration, Permanent Type of study: Evaluation studies Language: Portuguese Journal: Odonto (Säo Bernardo do Campo) Journal subject: Dentistry Year: 2017 Type: Article Affiliation country: Brazil Institution/Affiliation country: Universidade Federal de Santa Maria/BR