Good correlation between mixed and central venous oxygen variables in both hyperdynamic and normodynamic states
Mansoura Medical Journal. 1999; 29 (3-4): 49-57
in English
| IMEMR
| ID: emr-108360
ABSTRACT
This study was undertaken to assess whether or not central venous oxygen variables [CvO2] measurement can replace mixed venous oxygen variables [MvO2] measurement in two clinical settings, hyperdynamic kidney recipient [KR] and normodynamic patients subjected to radical cystectomy [RC]. MV and CV oxygen tension [PvO2], saturation [SvO2] and arteriovenous O2 content difference [a-vDO2] during the perioperative period of kidney transplantation [10 patients, 69 samples] and radical cystectomy [10 patients, 83 samples] under different FiO2 [0.21-0.35] were compared. The findings of this study demonstrate strong correlation between MvO2 and CvO2 variables in both hyperdynamic and normodynamic clinical settings
Search on Google
Index:
IMEMR (Eastern Mediterranean)
Main subject:
Oxygen
/
Arteries
/
Veins
/
Cystectomy
/
Kidney Transplantation
Limits:
Female
/
Humans
/
Male
Language:
English
Journal:
Mansoura Med. J.
Year:
1999
Similar
MEDLINE
...
LILACS
LIS