Good correlation between mixed and central venous oxygen variables in both hyperdynamic and normodynamic states
Mansoura Medical Journal. 1999; 29 (3-4): 49-57
in English | IMEMR | ID: emr-108360
ABSTRACT
This study was undertaken to assess whether or not central venous oxygen variables [CvO2] measurement can replace mixed venous oxygen variables [MvO2] measurement in two clinical settings, hyperdynamic kidney recipient [KR] and normodynamic patients subjected to radical cystectomy [RC]. MV and CV oxygen tension [PvO2], saturation [SvO2] and arteriovenous O2 content difference [a-vDO2] during the perioperative period of kidney transplantation [10 patients, 69 samples] and radical cystectomy [10 patients, 83 samples] under different FiO2 [0.21-0.35] were compared. The findings of this study demonstrate strong correlation between MvO2 and CvO2 variables in both hyperdynamic and normodynamic clinical settings
Subject(s)
Search on Google
Index: IMEMR (Eastern Mediterranean) Main subject: Oxygen / Arteries / Veins / Cystectomy / Kidney Transplantation Limits: Female / Humans / Male Language: English Journal: Mansoura Med. J. Year: 1999