Your browser doesn't support javascript.
loading
[ investigation of diagnostic accuracy of intraoperative frozen sections in Hirschsprung's disease]
Medical Journal of Mashad University of Medical Sciences. 2012; 55 (2): 76-80
in Persian | IMEMR | ID: emr-131406
ABSTRACT
Widespread use of one-stage pull-through technique for Hirschsprung's disease and its excellent results are dependent on the accuracy of intraoperative frozen sections [IOFS]. The purpose of the present study is to determine the incidence and sources of probable errors during this process. This cross-sectional study included all patients who were admitted from 2000 to 2010 in Dr Sheikh Children Hospital and had undergone IOFS for diagnosis of Hirschsprung's disease. This cross-sectional study included all patients who were admitted from 2000 to 2010 in Dr Sheikh Children Hospital and had undergone IOFS for diagnosis of Hirschsprung's disease. Frozen section can be a reliable method for evaluation of suspected Hirschsprung's patients with consideration that the favorable outcome is totally dependent on quality and number of prepared frozen sections for careful evaluation by pathologist
Subject(s)
Search on Google
Index: IMEMR (Eastern Mediterranean) Main subject: Cross-Sectional Studies / Frozen Sections Type of study: Prevalence study Limits: Humans Language: Persian Journal: Med. J. Mashad Univ. Med. Sci. Year: 2012