Need for chest tube after video assisted thoracoscopic [VATS] lung biopsy
Esculapio. 2012; 8 (3): 143-146
in En
| IMEMR
| ID: emr-147787
Responsible library:
EMRO
To observe the effects of early removal of chest tube drain after video assisted thoracoscopic [VATS] lung biopsy. We prospectively evaluated the removal of chest tube drain at six hours or 24 hours after the VATS-lung biopsy in fifty consecutive patients with no evidence of air leak after the lung biopsy. Our results show that removal of chest tube drain at 6 hours was not associated with complications such pneumothorax, atelectasis or pleural effusion as compared to the 24 hours removal of the drain[p>0.05]. Early removal of chest tube drain is safe in patients where air leak has been documented to be absent. Since it was a non-randomized evaluation, further randomized study in our population is needed to confirm these findings
Search on Google
Index:
IMEMR
Type of study:
Clinical_trials
Language:
En
Journal:
Esculapio
Year:
2012