Need for chest tube after video assisted thoracoscopic [VATS] lung biopsy
Esculapio. 2012; 8 (3): 143-146
in En | IMEMR | ID: emr-147787
Responsible library: EMRO
To observe the effects of early removal of chest tube drain after video assisted thoracoscopic [VATS] lung biopsy. We prospectively evaluated the removal of chest tube drain at six hours or 24 hours after the VATS-lung biopsy in fifty consecutive patients with no evidence of air leak after the lung biopsy. Our results show that removal of chest tube drain at 6 hours was not associated with complications such pneumothorax, atelectasis or pleural effusion as compared to the 24 hours removal of the drain[p>0.05]. Early removal of chest tube drain is safe in patients where air leak has been documented to be absent. Since it was a non-randomized evaluation, further randomized study in our population is needed to confirm these findings
Search on Google
Index: IMEMR Type of study: Clinical_trials Language: En Journal: Esculapio Year: 2012