When cheating goes wrong: hearing device migrated to the middle ear cavity
Bahrain Medical Bulletin. 2016; 38 (1): 48-49
in English | IMEMR | ID: emr-175709
ABSTRACT
A twenty-four-year-old Bahraini male presented to emergency with bloody discharge from the left ear and mild earache. History revealed insertion of a hearing device in the left external canal, which migrated to the middle ear cavity. The device was removed under general anaesthesia; one mm in diameter foreign body was extracted with a surgical hook through the tympanic membrane perforation. The patient did not suffer any major complication
Subject(s)
Search on Google
Index: IMEMR (Eastern Mediterranean) Main subject: Ear / Ear, Middle / Earache / Foreign Bodies / Hearing Type of study: Case report Limits: Adult / Humans / Male Language: English Journal: Bahrain Med. Bull. Year: 2016