Stability-indicating assay of secnidazole in the presence of its degradation products
Bulletin of Faculty of Pharmacy-Cairo University. 1999; 37 (3): 9-18
in English
| IMEMR
| ID: emr-50476
ABSTRACT
Four new selective, precise and accurate first derivative spectrophotometric, RP-HPLC, TLC densitometric and colorimetric methods were described for the determination of secnidazole in the presence of its degradation products, 2-methyl-5-nitroimidazole and hydroxy propanol. These methods were suitable for stability testing of secnidazole in bulk powder retaining their accuracy in the presence of up to 70% and 90% of its degradation product. The proposed methods were applied for the analysis of pharmaceutical formulations and the recoveries were 99.40-100.52%. The results obtained agreed with the reported method:
Search on Google
Index:
IMEMR (Eastern Mediterranean)
Main subject:
Spectrophotometry
/
Chromatography, High Pressure Liquid
/
Chromatography, Thin Layer
/
Colorimetry
/
Densitometry
/
Drug Stability
/
Nitroimidazoles
Language:
English
Journal:
Bull. Fac. Pharm.-Cairo Univ.
Year:
1999
Similar
MEDLINE
...
LILACS
LIS