Olecranon fractures treated by Weber Vasey technique
JSP-Journal of Surgery Pakistan International. 2000; 5 (2): 5-7
in English | IMEMR | ID: emr-54344
ABSTRACT
This prospective study is based on 36 patients with displaced olecranon fracture managed with open redaction and internal fixation [ORIF] by tension band wiring [TBW] to evaluate the functional results, to compare the results with published literature and to formulate future plan for this type of fracture management. Out of 36 patients, 29 [80 percent] scored good to fair results, seven [20 percent] scored poor including one non-union. We encountered higher than expected rate of minor complications like superficial infection in three [3.4 percent] patients, pain due to irritation by implant in 12 [33 percent], skin breakage in 6 [16.5 percent] and proximal migration of K wires in 4 [11 percent]
Subject(s)
Search on Google
Index: IMEMR (Eastern Mediterranean) Main subject: Postoperative Complications / Treatment Outcome Limits: Female / Humans / Male Language: English Journal: J. Surg. Pak. Int. Year: 2000