Your browser doesn't support javascript.
loading
Comparative analysis of the biochemical tests used to differentiate between pleural transudates and exudates
Scientific Journal of Al-Azhar Medical Faculty [Girls] [The]. 2000; 21 (Supp. 1): 877-884
in English | IMEMR | ID: emr-55644
ABSTRACT
This study aimed to evaluate the diagnostic accuracies for pleural fluid tests that discriminate between transudative and exudative pleural effusion. A prospective evaluation of 78 patients with pleural effusion of different etiologies was done. The criteria showed the best results in this series, four effusions only were misclassified [three transudates and one exudate]. The number of misclassified effusions in other criteria was seven by PF cholinesterase [three transudates and four exudates], six by the P/S cholinesterase [four transudates and two exudates], six by PF cholesterol [one transudate and five exudates] and five by PF/S cholesterol ratio [two transudates and three exudates]. It was concluded that the criteria of Light et al. were the best method for distinguishing exudates from transudates
Subject(s)
Search on Google
Index: IMEMR (Eastern Mediterranean) Main subject: Pleural Effusion / Pleural Effusion, Malignant / Exudates and Transudates Limits: Female / Humans / Male Language: English Journal: Sci. J. Al-Azhar Med. Fac. [Girls] Year: 2000

Similar

MEDLINE

...
LILACS

LIS

Search on Google
Index: IMEMR (Eastern Mediterranean) Main subject: Pleural Effusion / Pleural Effusion, Malignant / Exudates and Transudates Limits: Female / Humans / Male Language: English Journal: Sci. J. Al-Azhar Med. Fac. [Girls] Year: 2000