Scientific Journal of Al-Azhar Medical Faculty [Girls] [The]. 2000; 21 (Supp. 1): 1413-1419
in En
| IMEMR
| ID: emr-55690
Responsible library:
EMRO
A biometric study using A-mode ultrasonography was performed on 45 eyes with and without ocular accommodation. During accommodation, an increased Lt and decreased anterior chamber death [ACD] were noted in group I only. The axial length was not significantly changed during accommodation or after the offset of any accommodative effect. It was concluded that axial length [AL] measurement performed on a dilated pupil can give an accurate result that was not statistically different than those obtained without papillary dilatation
Search on Google
Index:
IMEMR
Main subject:
Biometry
/
Ultrasonography
/
Lenses, Intraocular
/
Anterior Chamber
Type of study:
Diagnostic_studies
Limits:
Humans
Language:
En
Journal:
Sci. J. Al-Azhar Med. Fac. [Girls]
Year:
2000