Fogarty catheter for a difficult bronchial foreign body removal: [case report]
Tehran University Medical Journal [TUMJ]. 2007; 65 (Supp. 2): 65-69
in English, Persian
| IMEMR
| ID: emr-85490
ABSTRACT
There are many methods for removal of tracheobronchial foreign bodies but there are many situations where removal of a foreign body seems impossible and may require a major surgical procedure. Familiarity with each method improves physician decision making. Case A 17 months old baby with a history of foreign body aspiration suffered from long term pneumonia. There was a round shape foreign body in bronchoscopic view that could not be removed with standard methods, but was removed by application of Fogarty catheter. Conclusion:
Removal of round, spherical foreign bodies may be performed by Fogarty Catheter preventing surgical intervention