Background:
parathyroid scintigraphy with Tc99m Sestamibi, a tracer that is taken up by byperfuncttoning parathyroid tissue, has a high yield in the diagnosis of abnormal parathyroid grouths.Aim:
to assess the usefulness of parathyroid scintigraphy with Tc99m Sestamibi in patients with suspected hyperparathyroidism. Patients andmethods:
we analyzed retrospectively 29 patients with suspected hyperparathyroidism, in whom a scintigraphy with Tc99m Sestamibi was performed.Results:
twenty four of 25 patients in whom hyperfuntioning parathyroid tissue was evidenced with scintigraphy, were operated. Histological diagnosis of the escised parathyroid gland, showed 23 adenomas and 1 hyperplasia. Anatomical location disclosed by scintigraphy was concordant with surgical finding in all cases, including a mediastinic adenoma. Of the four patients with negative scintigraphic findings, two had transitory PTH elevations and in two the presence of adenoma or hyperplasia could not be demonstrated with other diagnostic procedures.Conclusions:
parathyroid scintigraphy with Tc99m Sestamibi had an 86 percent sensitivity for the detection of hyperfunctioning parathyroid tissue in patients with elevated PTH
Search on Google
Index:
LILACS (Americas)
Main subject:
Parathyroid Neoplasms
/
Technetium Tc 99m Sestamibi
Type of study:
Diagnostic study
Limits:
Adult
/
Female
/
Humans
/
Male
Language:
Spanish
Journal:
Rev. méd. Chile
Journal subject:
Medicine
Year:
1997
Type:
Article
Similar
MEDLINE
...
LILACS
LIS