Your browser doesn't support javascript.
loading
Comissurotomia mitral mecanica pertutanea utilizando o valvótomo metálico de Cribier. Resultados iniciais / Percutaneous mechanical mitral commissurotomy performed with a Cribier's metallic valvulotome. Initial results
Bastos, Maria Dias de Azeredo; Esteves, César A; Araújo, David; Bastos, Luciene Ap. M. A; Eistein, Magno; Santana, Geraldo Paulino; Oliveira, Gilson José de; Brasil, Luiz; Calzada, Antônio; Calzada, Delzirene Botelho; Pereira, José; Sales, Rômulo; Olivera, Nivaldo Gomes de.
Affiliation
  • Bastos, Maria Dias de Azeredo; Santa Casa de Misericórdia de Goiania. Goiania. BR
  • Esteves, César A; Santa Casa de Misericórdia de Goiania. Goiania. BR
  • Araújo, David; Santa Casa de Misericórdia de Goiania. Goiania. BR
  • Bastos, Luciene Ap. M. A; Santa Casa de Misericórdia de Goiania. Goiania. BR
  • Eistein, Magno; Santa Casa de Misericórdia de Goiania. Goiania. BR
  • Santana, Geraldo Paulino; Santa Casa de Misericórdia de Goiania. Goiania. BR
  • Oliveira, Gilson José de; Santa Casa de Misericórdia de Goiania. Goiania. BR
  • Brasil, Luiz; Santa Casa de Misericórdia de Goiania. Goiania. BR
  • Calzada, Antônio; Santa Casa de Misericórdia de Goiania. Goiania. BR
  • Calzada, Delzirene Botelho; Santa Casa de Misericórdia de Goiania. Goiania. BR
  • Pereira, José; Santa Casa de Misericórdia de Goiania. Goiania. BR
  • Sales, Rômulo; Santa Casa de Misericórdia de Goiania. Goiania. BR
  • Olivera, Nivaldo Gomes de; Santa Casa de Misericórdia de Goiania. Goiania. BR
Arq. bras. cardiol ; 77(2): 120-131, Aug. 2001. ilus, tab
Article in Pt, En | LILACS | ID: lil-289681
Responsible library: BR1.1
ABSTRACT

OBJECTIVE:

To evaluate the immediate results of percutaneous mechanical mitral commissurotomy.

METHODS:

Thirty patients underwent percutaneous mechanical mitral commissurotomy performed with a Cribier's metallic valvulotome from 8/11/99 to 2/4/00. Mean age was 30.7 years, and 73.3 percent were women. With regards to functional class, 63.3 percent were class III, and 36.7 percent were class IV. The echocardiographic score had a mean value of 7.5 + or - 1.8.

RESULTS:

The mitral valve area increased from 0.97 + or - 0.15cm² to 2.16 + or - 0.50cm² (p>0.0001). The mean diastolic gradient decreased from 17.9 + or - 5.0mmHg to 3.2 + or - 1.4mmHg. The mean left atrial pressure decreased from 23.6 + or - 5.4mmHg to 8.6 + or - 3.1mmHg, (p>0.0001). Systolic pressure in the pulmonary artery decreased from 52.7 + or - 18.3mmHg to 32.2 + or - 7.4mmHg. Twenty-nine cases were successful. One patient developed severe mitral regurgitation. Interatrial septal defect was observed and one patient. One patient had cardiac tamponade due to left ventricular perforation. No deaths occurred.

CONCLUSION:

This method has proven to be safe and efficient in the treatment of rheumatic mitral stenosis. The potential advantage is that it can be used multiple times after sterilization, which decreases procedural costs significantly
Subject(s)
Full text: 1 Index: LILACS Main subject: Mitral Valve Stenosis Limits: Adult / Female / Humans / Male Language: En / Pt Journal: Arq. bras. cardiol Journal subject: CARDIOLOGIA Year: 2001 Type: Article
Full text: 1 Index: LILACS Main subject: Mitral Valve Stenosis Limits: Adult / Female / Humans / Male Language: En / Pt Journal: Arq. bras. cardiol Journal subject: CARDIOLOGIA Year: 2001 Type: Article