Your browser doesn't support javascript.
loading
Influência do procedimento radiográfico na dose de entrada na pele de pacientes em raios-X pediátricos / Influence of radiographic parameters on the entrance surface dose in x-rays of pediatric patients
Oliveira, Mércia Liane; Khoury, Helen.
  • Oliveira, Mércia Liane; Comissão Nacional de Energia Nuclear. Instituto de Pesquisas Energéticas e Nucleares. São Paulo. BR
  • Khoury, Helen; Universidade Federal de Pernambuco. Departamento de Energia Nuclear. Recife. BR
Radiol. bras ; 36(2): 105-109, mar.-abr. 2003. tab, graf
Article in Portuguese | LILACS | ID: lil-337820
RESUMO

OBJETIVO:

Este trabalho tem como objetivo discutir os efeitos dos principais parâmetros que interferem na qualidade da imagem e na dose de entrada na pele do paciente.

MATERIAIS E MÉTODOS:

Foram acompanhadas radiografias pediátricas de tórax em três instituições. Em cada uma delas foram feitos testes de desempenho dos equipamentos de raios-X utilizados. A avaliação da dose de entrada na pele foi feita com a utilização de dosímetros termoluminescentes.

RESULTADOS:

Apenas um dos equipamentos de raios-X testados mostrou-se em condições aceitáveis de funcionamento. Os valores médios de dose de entrada na pele para os exames investigados, em função da faixa etária, foram (0,22 ± 0,88) mGy para menores de 1 ano, (0,28 ± 0,11) mGy entre 1,1 e 4 anos, (0,26 ± 0,13) mGy entre 4,1 e 6 anos, (0,23 ± 0,13) mGy entre 6,1 e 10 anos e (0,26 ± 0,25) mGy para maiores de 10 anos.

CONCLUSÃO:

Os valores médios de dose de entrada na pele são bastante elevados se comparados aos níveis de referência adotados pela Comissão da Comunidade Européia e aos demais resultados encontrados na literatura pesquisada. Recomenda-se a implantação de programas de garantia de qualidade para a redução da dose-paciente com a obtenção de imagens com qualidade para o diagnóstico
ABSTRACT

OBJECTIVE:

The aim of this work is to discuss the effects of the main parameters that influence image quality and the entrance skin dose. MATERIALS AND

METHODS:

The pediatric chest radiographs of three different Institutions were evaluated. Tests on all x-ray equipment were performed. The skin entrance dose was assessed using thermoluminescent dosimeters.

RESULTS:

Only one of all x-ray equipments tested was in good operation condition. The average skin entrance dose was (0.222 ± 0.088) mGy for children under 1 year, (0.28 ± 0.11) mGy for 1.1 to 4 years, (0.26 ± 0.13) mGy for 4.1 to 6 years, (0.23 ± 0.13) mGy for 6.1 to 10 years and (0.26 ± 0.25) mGy for older than 10 years.

CONCLUSION:

The results showed that the average skin entrance doses are higher than the European Community Commission reference levels and other values reported in the literature. We recommend the implantation of quality assurance programs to reduce skin entrance doses and for obtaining good quality images.
Subject(s)
Full text: Available Index: LILACS (Americas) Main subject: Pediatrics / Radiology / Radiotherapy Dosage / Skin / Dose-Response Relationship, Radiation Limits: Adolescent / Child / Child, preschool / Female / Humans / Infant / Male / Infant, Newborn Language: Portuguese Journal: Radiol. bras Journal subject: Diagnostic Imaging / Radiology Year: 2003 Type: Article Affiliation country: Brazil Institution/Affiliation country: Comissão Nacional de Energia Nuclear/BR / Universidade Federal de Pernambuco/BR

Similar

MEDLINE

...
LILACS

LIS

Full text: Available Index: LILACS (Americas) Main subject: Pediatrics / Radiology / Radiotherapy Dosage / Skin / Dose-Response Relationship, Radiation Limits: Adolescent / Child / Child, preschool / Female / Humans / Infant / Male / Infant, Newborn Language: Portuguese Journal: Radiol. bras Journal subject: Diagnostic Imaging / Radiology Year: 2003 Type: Article Affiliation country: Brazil Institution/Affiliation country: Comissão Nacional de Energia Nuclear/BR / Universidade Federal de Pernambuco/BR