Your browser doesn't support javascript.
loading
Elaboração e implementação de um programa para verificação dos cálculos das unidades monitoras em radioterapia / Development and implementation of a software for assessment of calculations in radiotherapy monitor units
Müller, Márcio Rogério; Rodrigues, Laura Natal; Silva, Marco Antônio da.
  • Müller, Márcio Rogério; Universidade de São Paulo. Instituto de Pesquisas Energéticas e Nucleares. São Paulo. BR
  • Rodrigues, Laura Natal; Universidade Federal do Rio de Janeiro. Rio de Janeiro. BR
  • Silva, Marco Antônio da; Universidade de São Paulo. Instituto de Pesquisas Energéticas e Nucleares. São Paulo. BR
Radiol. bras ; 38(6): 415-420, nov.-dez. 2005. ilus, tab, graf
Article in Portuguese | LILACS | ID: lil-421244
RESUMO

OBJETIVO:

Desenvolvimento e implementação de um programa, fundamentado no algoritmo de cálculo manual, para verificação dos cálculos de unidades monitoras em radioterapia e estabelecimento de patamares de aceitação, como mecanismo de garantia da qualidade.

MATERIAIS E MÉTODOS:

Os dados apresentados foram obtidos a partir dos aceleradores lineares modelo Clinac 600C e 2100C, da Varian, e o sistema de planejamento de tratamento computadorizado utilizado foi o CadPlanÕ.

RESULTADOS:

Para os feixes de 6 MV os patamares de aceitação para desvios entre os cálculos de unidades monitoras, separados por região de tratamento, foram mama (0,0 por cento ± 1,7 por cento), cabeça e pescoço (1,5 por cento ± 0,5 por cento), hipófise (-1,7 por cento ± 0,5 por cento), pelve (2,1 por cento ± 2,1 por cento) e tórax (0,2 por cento ± 1,3 por cento). Para os feixes de 15 MV, o patamar sugerido para pelve em todas as técnicas de tratamento foi de (3,2 por cento ± 1,3 por cento).

CONCLUSÃO:

Os dados são suficientes para justificar seu uso na prática clínica como ferramenta no programa de garantia da qualidade.
ABSTRACT

OBJECTIVE:

To develop and implement a software based on the manual calculation algorithm for verification of the calculations in radiotherapy monitor units and to establish acceptance levels as a mechanism of quality assurance. MATERIALS AND

METHODS:

Data were obtained from Clinac 600C and 2100C Varian linear accelerators and the computerized treatment planning system used was CadPlan™.

RESULTS:

For the 6 MV beams the acceptance levels for deviations among the calculations of monitor units, divided by treatment area, were the following breast (0.0% ± 1.7%), head and neck (1.5% ± 0.5%), hypophysis (–1.7% ± 0.5%), pelvis (2.1% ± 2.1%) and thorax (0.2% ± 1.3%). For the 15 MV beams the suggested level for pelvis in all the treatment techniques was (3.2% ± 1.3%).

CONCLUSION:

The present data are sufficient to justify the use of the software in the clinical practice as a tool for the quality assurance program.
Subject(s)
Full text: Available Index: LILACS (Americas) Main subject: Radiotherapy / Algorithms / Radiation Monitoring / Environmental Monitoring / Planning Type of study: Practice guideline / Systematic review of observational studies Language: Portuguese Journal: Radiol. bras Journal subject: Diagnostic Imaging / Radiology Year: 2005 Type: Article Affiliation country: Brazil Institution/Affiliation country: Universidade Federal do Rio de Janeiro/BR / Universidade de São Paulo/BR

Similar

MEDLINE

...
LILACS

LIS

Full text: Available Index: LILACS (Americas) Main subject: Radiotherapy / Algorithms / Radiation Monitoring / Environmental Monitoring / Planning Type of study: Practice guideline / Systematic review of observational studies Language: Portuguese Journal: Radiol. bras Journal subject: Diagnostic Imaging / Radiology Year: 2005 Type: Article Affiliation country: Brazil Institution/Affiliation country: Universidade Federal do Rio de Janeiro/BR / Universidade de São Paulo/BR