Experiencia en el uso de un nuevo catéter electrodo de estimulación endocavitaria: Seguimiento a un año / Experience in the use of a new endocardial stimulation electrode
Frangini S., Patricia; Vergara S., Ismael; González A., Rolando; Baeza L., Mariana; Cambón R., Ana María.
  • Frangini S., Patricia; Pontificia Universidad Católica de Chile. Facultad de Medicina. Departamento de Enfermedades Cardiovasculares. Laboratorio de Electrofisiología Cardíaca. Santiago. CL
  • Vergara S., Ismael; Pontificia Universidad Católica de Chile. Facultad de Medicina. Departamento de Enfermedades Cardiovasculares. Laboratorio de Electrofisiología Cardíaca. Santiago. CL
  • González A., Rolando; Pontificia Universidad Católica de Chile. Facultad de Medicina. Departamento de Enfermedades Cardiovasculares. Laboratorio de Electrofisiología Cardíaca. Santiago. CL
  • Baeza L., Mariana; s.af
  • Cambón R., Ana María; s.af
Rev. méd. Chile ; 134(6): 749-753, jun. 2006. ilus, tab, graf
Article in Spanish | LILACS | ID: lil-434623
ABSTRACT
Background: Since February 2002, Flextend® electrode catheters are used at the Cardiovascular Unit of the Catholic University Clinical Hospital. These transvenous catheters have an IS-1 connector, silicone coating, active fixation and retractile helix with dexamethasone acetate. Aim: To report early and one year results using Flextend® catheters. Material and methods: Retrospective analysis of all patients that received an implant of a Flextend® catheter in the Unit. Results: Forty one Flextend® catheters were implanted in 24 patients, without acute displacement or clinical pericarditis. In 18 electrode catheters located in the right atrium the mean values for p wave, stimulation threshold and impedance at the moment of placement, were 2.9±1.4 mV, 0.8±0.4 V and 522±86 Ohms, respectively. The figures 24 hours after placement were 3.6±2.1 mV, 0.8±0.3 V and 612±69 Ohms, respectively. In 23 electrode catheters in the right ventricle, mean values at the moment of placement for R wave, stimulation threshold and impedance were 11.3±3.6 mV, 0.8±0.2 V and 756±108 Ohms, respectively. The figures 24 hours after placement were 3.6±2.1 mV, 0.8±0.3 V and 612±69 Ohms, respectively. In one patient, the stimulation threshold increased two months after placement and required a new intervention. Conclusions: Flextend® catheters ca be placed successfully with a low rate of complications and stable function parameters on follow up.
Subject(s)
Full text: Available Index: LILACS (Americas) Main subject: Pacemaker, Artificial / Technology Assessment, Biomedical / Electric Stimulation / Electrodes, Implanted Type of study: Evaluation studies / Health technology assessment / Observational study / Prognostic study Limits: Adult / Aged / Aged80 / Female / Humans / Male Language: Spanish Journal: Rev. méd. Chile Journal subject: Medicine Year: 2006 Type: Article Affiliation country: Chile Institution/Affiliation country: Pontificia Universidad Católica de Chile/CL

Similar

MEDLINE

...
LILACS

LIS

Full text: Available Index: LILACS (Americas) Main subject: Pacemaker, Artificial / Technology Assessment, Biomedical / Electric Stimulation / Electrodes, Implanted Type of study: Evaluation studies / Health technology assessment / Observational study / Prognostic study Limits: Adult / Aged / Aged80 / Female / Humans / Male Language: Spanish Journal: Rev. méd. Chile Journal subject: Medicine Year: 2006 Type: Article Affiliation country: Chile Institution/Affiliation country: Pontificia Universidad Católica de Chile/CL