Your browser doesn't support javascript.
loading
Seguimiento en fase aguda de catpeteres electrodos de estimulación endocavitaria permanente: Comparación de tres modelos / Comparison of three brands of intracardiac pacemarker leads
Frangini S., Patricia; Vergara S., Ismael; González A., Rolando; Fajuri N., Alejandro; Baeza L., Mariana.
  • Frangini S., Patricia; Pontificia Universidad Católica de Chile. Facultad de Medicina. Departamento de Enfermedades Cardiovasculares. Laboratorio de Electrofisiología Cardíaca. Santiago. CL
  • Vergara S., Ismael; Pontificia Universidad Católica de Chile. Facultad de Medicina. Departamento de Enfermedades Cardiovasculares. Laboratorio de Electrofisiología Cardíaca. Santiago. CL
  • González A., Rolando; Pontificia Universidad Católica de Chile. Facultad de Medicina. Departamento de Enfermedades Cardiovasculares. Laboratorio de Electrofisiología Cardíaca. Santiago. CL
  • Fajuri N., Alejandro; Pontificia Universidad Católica de Chile. Facultad de Medicina. Departamento de Enfermedades Cardiovasculares. Laboratorio de Electrofisiología Cardíaca. Santiago. CL
  • Baeza L., Mariana; Pontificia Universidad Católica de Chile. Facultad de Medicina. Departamento de Enfermedades Cardiovasculares. Laboratorio de Electrofisiología Cardíaca. Santiago. CL
Rev. méd. Chile ; 134(11): 1427-1435, nov. 2006. ilus, tab
Article in Spanish | LILACS | ID: lil-439938
ABSTRACT
Background: Electrode lead design and materials influence their performance, stability and manipulation characteristics. In our laboratory, we use straight intracardiac, active fixation, steroid eluting leads. These features are shared by three brands of pacemarker distributors. Aim: To compare the short term results of three brands of leads used in our laboratory in patients requiring the implant of a pacemarker of cardioverter. Material and methods: One hundred and four patients (mean age 70 years, 59 males) subjected to a pacemarker or cardioverter implant were studied and followed during the first three months post implant. In these patients, 49 Guidant Flextend® 4087 or 4088, 27 Saint Jude Tendril® 1488T and 10 Medtronic Capsurefix® 5076 leads were implanted in the right atrium and 60 Guidant Flextend® 4087 or 4088, 29 Saint Jude Tendril® 1488T and 19 Medtronic Capsurefix® 5076 leads were implanted in the right ventricle. Results: Implant parameters were adequate for all leads. A sub-acute rise in ventricular stimulation threshold was detected in one Flextrend® lead. Three atrial leads (two Flextend® and one Capsurefix®) and one Capsurefix® ventricular lead experienced an acute displacement. One patient with a Flextend® lead, had a cardiac tamponade caused by an atrial perforation. Conclusions: The three brands of leads tested can be successfully implanted with comparable parameters and without differences in the evolution of patients during the first three months.
Subject(s)
Full text: Available Index: LILACS (Americas) Main subject: Pacemaker, Artificial / Arrhythmias, Cardiac / Defibrillators, Implantable Type of study: Observational study / Prognostic study Limits: Adult / Aged / Aged80 / Female / Humans / Male Language: Spanish Journal: Rev. méd. Chile Journal subject: Medicine Year: 2006 Type: Article Affiliation country: Chile Institution/Affiliation country: Pontificia Universidad Católica de Chile/CL

Similar

MEDLINE

...
LILACS

LIS

Full text: Available Index: LILACS (Americas) Main subject: Pacemaker, Artificial / Arrhythmias, Cardiac / Defibrillators, Implantable Type of study: Observational study / Prognostic study Limits: Adult / Aged / Aged80 / Female / Humans / Male Language: Spanish Journal: Rev. méd. Chile Journal subject: Medicine Year: 2006 Type: Article Affiliation country: Chile Institution/Affiliation country: Pontificia Universidad Católica de Chile/CL