Your browser doesn't support javascript.
loading
Spatio-temporal image correlation (STIC): nova técnica para avaliação do coração fetal / Spatio-temporal image correlation (STIC): a new technique for fetal heart evaluation
Araujo Júnior, Edward; Zanforlin Filho, Sebastião Marques; Pires, Cláudio Rodrigues; Guimarães Filho, Hélio Antônio; Nardozza, Luciano Marcondes Machado; Moron, Antonio Fernandes.
  • Araujo Júnior, Edward; Universidade Federal de São Paulo. Departamento de Obstetrícia. São Paulo. BR
  • Zanforlin Filho, Sebastião Marques; Universidade Federal de São Paulo. Centro de Treinamento em Ultra-sonografia de São Paulo. São Paulo. BR
  • Pires, Cláudio Rodrigues; Universidade Federal de São Paulo. Centro de Treinamento em Ultra-sonografia de São Paulo. São Paulo. BR
  • Guimarães Filho, Hélio Antônio; Universidade Federal de São Paulo. Departamento de Obstetrícia. São Paulo. BR
  • Nardozza, Luciano Marcondes Machado; Universidade Federal de São Paulo. Departamento de Obstetrícia. São Paulo. BR
  • Moron, Antonio Fernandes; Universidade Federal de São Paulo. Departamento de Obstetrícia. São Paulo. BR
Radiol. bras ; 39(5): 373-377, set.-out. 2006. ilus
Article in Portuguese | LILACS | ID: lil-446732
RESUMO
As malformações cardíacas são as mais freqüentes anomalias congênitas ao nascimento, entretanto, a sua detecção pré-natal pela ultra-sonografia convencional permanece baixa. As ultra-sonografias de terceira e quarta dimensões surgiram no início da década de 90, apresentando grandes aplicações em obstetrícia, principalmente nos casos de diagnósticos duvidosos à ultra-sonografia bidimensional. O spatio-temporal image correlation (STIC) representa grande avanço na área de ultra-som de quarta dimensão; constitui-se em um software acoplado ao aparelho Voluson 730 Expert, que permite a aquisição volumétrica do coração fetal e suas conexões vasculares. As análises volumétricas são realizadas nos modos multiplanar e de renderização, podendo-se também utilizar o Doppler. Apresenta, como grandes vantagens, a aquisição rápida e a possibilidade de análise posterior por especialistas em ecocardiografia fetal. Pode ser aplicada para a pesquisa de quaisquer cardiopatias congênitas, pois permite a aquisição de qualquer plano, diferentemente do ultra-som bidimensional. Sua principal desvantagem está relacionada aos movimentos fetais. A maior difusão do método pode permitir um aumento na detecção de malformações cardíacas, pois possibilita ao ultra-sonografista geral encaminhar, via Internet, os volumes para a análise por especialistas em ecocardiografia fetal.
ABSTRACT
Although congenital heart defect is the most frequent anomaly in newborns, its antenatal detection rate through conventional ultrasound remains low. 3D and 4D ultrasound technology was developed early in the nineties, bringing great benefits in obstetrics, especially in cases of dubious diagnosis at 2D ultrasound. The spatio-temporal image correlation (STIC) is a significant development in the field of 4D ultrasound. A software coupled with a Voluson 730 Expert equipment allows a volumetric acquisition of the fetal heart and its vascular connections. Volumetric analyses are performed in multiplanar and surface rendering modes or, alternatively in association with color Doppler. Major advantages are fast images acquisition and the possibility of a later analysis by fetal echocardiography specialists. Differently from 2D ultrasound, this technique may be applied for evaluating any congenital cardiopathy because of the increased number of frames acquired from a specific anatomical region. Main disadvantage is related to the necessity of fetal immobility. The higher diffusion of this method may improve prenatal detection of heart malformations since volumes data captured by a sonographer may be sent through the Internet for analysis by fetal echocardiography specialists.
Subject(s)
Full text: Available Index: LILACS (Americas) Main subject: Ultrasonography, Prenatal / Echocardiography, Three-Dimensional / Fetal Heart / Heart Defects, Congenital Type of study: Diagnostic study Limits: Pregnancy Language: Portuguese Journal: Radiol. bras Journal subject: Diagnostic Imaging / Radiology Year: 2006 Type: Article Affiliation country: Brazil Institution/Affiliation country: Universidade Federal de São Paulo/BR

Similar

MEDLINE

...
LILACS

LIS

Full text: Available Index: LILACS (Americas) Main subject: Ultrasonography, Prenatal / Echocardiography, Three-Dimensional / Fetal Heart / Heart Defects, Congenital Type of study: Diagnostic study Limits: Pregnancy Language: Portuguese Journal: Radiol. bras Journal subject: Diagnostic Imaging / Radiology Year: 2006 Type: Article Affiliation country: Brazil Institution/Affiliation country: Universidade Federal de São Paulo/BR