Your browser doesn't support javascript.
loading
Confiabilidade inter e intra-examinador da fotopodometria e intra-examinador da fotopodoscopia / Inter and intra-examiner reliability of photopodometry and intra-examiner reliability of photopodoscopy
Ribeiro, A. P; Trombini-Souza, F; Iunes, D. H; Monte-Raso, V. V.
  • Ribeiro, A. P; Universidade José do Rosário Vellano. Clínica de Fisioterapia. Departamento de Fisioterapia. Alfenas. BR
  • Trombini-Souza, F; Universidade José do Rosário Vellano. Clínica de Fisioterapia. Departamento de Fisioterapia. Alfenas. BR
  • Iunes, D. H; Universidade José do Rosário Vellano. Clínica de Fisioterapia. Departamento de Fisioterapia. Alfenas. BR
  • Monte-Raso, V. V; Universidade José do Rosário Vellano. Clínica de Fisioterapia. Departamento de Fisioterapia. Alfenas. BR
Braz. j. phys. ther. (Impr.) ; 10(4): 435-439, out.-dez. 2006. ilus, tab
Article in Portuguese | LILACS | ID: lil-448256
RESUMO
OBJETIVO: O propósito deste estudo foi avaliar a confiabilidade inter e intra-examinador da fotopodometria, bem como a confiabilidade intra-examinador da fotopodoscopia. MÉTODO: Foram fotografadas as impressões plantares de 30 indivíduos hígidos de ambos os sexos, com idade média de 21,0 ±1,32 anos, posicionados sobre um podoscópio, com os pés descalços, apoio bipodal e postura ortostática. A imagem da impressão plantar refletida no vidro desse aparelho foi capturada por meio de uma câmera fotográfica digital de 2.1 megapixels, posicionada sobre um tripé em frente ao mesmo. As imagens foram arquivadas e, em seguida, submetidas às análises inter e intra-examinador. Para verificar a confiabilidade intra-examinador da fotopodoscopia, após quatro semanas, toda a metodologia de captura e análise de novos podogramas dos mesmos indivíduos foi repetida. RESULTADOS: As análises inter e intra-examinador da fotopodometria apresentaram, respectivamente, ICC= 0,96 e ICC= 0,98. O ICC de confiabilidade intra-examinador da fotopodoscopia foi de 0,94. CONCLUSÃO: Conclui-se então que a fotopodometria é um recurso de análise quantitativa confiável, sendo também a fotopodoscopia um método de avaliação aplicável para análises clínicas e científicas, permitindo, assim, acompanhar a evolução de tratamentos fisioterapêuticos dos apoios plantares, mesmo levando-se em consideração as variabilidades intrínsecas e extrínsecas dos indivíduos.
ABSTRACT
OBJECTIVE: To evaluate the inter and intra-examiner reliability of photopodometry and the intra-examiner reliability of photopodoscopy. METHOD: Plantar prints from 30 healthy individuals of both sexes with mean age of 21.0 ± 1.32 years were photographed. These individuals were positioned on a podoscope with bare feet, bipedal support and orthostatic posture. The plantar print images reflected on the glass of this instrument were captured using a 2.1 megapixel digital photographic camera positioned on a tripod in front of the podoscope. The images were filed and subsequently subjected to inter and intra-examiner analysis. To verify the intra-examiner reliability of photopodoscopy, the whole procedure of podogram capture and analysis was repeated on the same individuals four weeks later. RESULTS: The intraclass correlation coefficients (ICC) for the inter and intra-examiner analyses on the photopodometry were, respectively, 0.96 and 0.98. The ICC for the intra-examiner reliability of the photopodometry was 0.94. CONCLUSION: Photopodometry is a reliable quantitative analysis method and photopodoscopy is an evaluation method applicable to clinical and scientific analyses. They therefore make it possible to follow up the evolution of physiotherapeutic treatment on plantar supports, despite the intrinsic and extrinsic variability between individuals.
Full text: Available Index: LILACS (Americas) Language: Portuguese Journal: Braz. j. phys. ther. (Impr.) Journal subject: MEDICINA FISICA E REABILITACAO Year: 2006 Type: Article Affiliation country: Brazil Institution/Affiliation country: Universidade José do Rosário Vellano/BR

Similar

MEDLINE

...
LILACS

LIS

Full text: Available Index: LILACS (Americas) Language: Portuguese Journal: Braz. j. phys. ther. (Impr.) Journal subject: MEDICINA FISICA E REABILITACAO Year: 2006 Type: Article Affiliation country: Brazil Institution/Affiliation country: Universidade José do Rosário Vellano/BR