RESUMO
A poluição sonora ambiental torna-se hoje onipresente e beira o intolerável. Nos hospitais, os avanços tecnológicos trazem, como conseqüência, níveis de ruído potencialmente danosos. Muito do ruído no hospital provém mais de dentro, do que de fora desse ambiente, sendo as principais causas de ruído em Unidade de Terapia Intensiva, por exemplo, os equipamentos e a conversação entre a equipe hospitalar. O objetivo deste trabalho foi avaliar o nível de ruído nos diversos ambientes hospitalares, em Hospital de 222 leitos na 18ª RS de Saúde - PR.

MATERIAIS E MÉTODOS:

Conduziu-se, em março de 2005 no período de 24 horas, em dez setores. Forma de Estudo Aferição do nível de ruído ambiental utilizando um Decibelímetro modelo 1350.

RESULTADOS:

O nível de ruído encontrado em nosso estudo apresentou média total de 63,7 dB(A), que excede os valores máximos permitidos de 45 dB recomendados pela Associação Brasileira de Normas Técnicas (1987).

CONCLUSÃO:

Nos setores analisados, o nível de ruído encontrado neste está consideravelmente acima do recomendado. A equipe hospitalar deve estar consciente do ruído e dos efeitos deste, para que possa atuar de maneira mais efetiva na redução da poluição sonora, beneficiando assim a função laborativa dos profissionais e recuperação dos pacientes.
ABSTRACT
Environment noise pollution is common place today, at intolerable levels. In hospitals, technological developments have, as a consequence, potentially harmful noise levels. Much of the hospital noise comes from inside, rather than outside, and the major source of such noise is the Intensive Care Unit, for example equipment and hospital staff talk. Our goal with the present study was to investigate the noise level present in the different hospital environments, within a 222 bed hospital located at the 18th health zone, PR. MATERIALS AND

METHODS:

The study was carried out in March, 2005, during a period of 24 hours, in tem different sectors. CASE STUDY We checked environmental sound level by means of a model 1350 decibel meter.

RESULTS:

The sound level found in our study was of 63.7 dB(A) in average, which exceeds the 45 dB recommended by the Brazilian Association of Technical Standards (1987).

CONCLUSION:

In the analyzed sectors, the sound level was considerably above the recommended maximum. The hospital staff should be aware of this noise level and its effects, so that they may act in a more efficient way in order to reduce this noise pollution; thus benefiting the professionals and patient recovery.
Subject(s)
Full text: Available Index: LILACS (Americas) Main subject: Hospital Units / Noise / Noise, Occupational Type of study: Practice guideline Limits: Humans Country/Region as subject: South America / Brazil Language: Portuguese Journal: Rev. bras. otorrinolaringol Journal subject: Otolaryngology Year: 2007 Type: Article

Similar

MEDLINE

...
LILACS

LIS

Full text: Available Index: LILACS (Americas) Main subject: Hospital Units / Noise / Noise, Occupational Type of study: Practice guideline Limits: Humans Country/Region as subject: South America / Brazil Language: Portuguese Journal: Rev. bras. otorrinolaringol Journal subject: Otolaryngology Year: 2007 Type: Article