Your browser doesn't support javascript.
loading
Freqüência cardíaca máxima em esteira ergométrica em diferentes horários / Frecuencia cardíaca máxima en cinta ergométrica a diferentes horarios / Maximal heart rate on treadmill at different times
Afonso, Leandro dos Santos; Santos, João Fernando Brinkmann dos; Lopes, José Ricardo; Tambelli, Rodrigo; Santos, Eduardo Henrique Rosa; Back, Flavio Augustino; Menna-Barreto, Luiz; Lima, Jorge Roberto Perrout de.
  • Afonso, Leandro dos Santos; Universidade Federal de Juiz de Fora. Faculdade de Educação Física e Desportos. Laboratório de Avaliação Motora. Juiz de Fora. BR
  • Santos, João Fernando Brinkmann dos; Universidade Bandeirante de São Paulo. Laboratório de Fisiologia do Exercício e Cineantropometria. São Paulo. BR
  • Lopes, José Ricardo; Universidade de São Paulo. Instituto de Ciências Biomédicas. Grupo Multidisciplinar de Desenvolvimento e Ritmos Biológicos. São Paulo. BR
  • Tambelli, Rodrigo; Universidade de São Paulo. Instituto de Ciências Biomédicas. Grupo Multidisciplinar de Desenvolvimento e Ritmos Biológicos. São Paulo. BR
  • Santos, Eduardo Henrique Rosa; Universidade de São Paulo. Instituto de Ciências Biomédicas. Grupo Multidisciplinar de Desenvolvimento e Ritmos Biológicos. São Paulo. BR
  • Back, Flavio Augustino; Universidade de São Paulo. Instituto de Ciências Biomédicas. Grupo Multidisciplinar de Desenvolvimento e Ritmos Biológicos. São Paulo. BR
  • Menna-Barreto, Luiz; Universidade de São Paulo. Instituto de Ciências Biomédicas. Grupo Multidisciplinar de Desenvolvimento e Ritmos Biológicos. São Paulo. BR
  • Lima, Jorge Roberto Perrout de; Universidade Federal de Juiz de Fora. Faculdade de Educação Física e Desportos. Laboratório de Avaliação Motora. Juiz de Fora. BR
Rev. bras. med. esporte ; 12(6): 318-322, nov.-dez. 2006. tab, graf
Article in Portuguese | LILACS | ID: lil-454209
RESUMO
Como muitas medidas do desempenho humano apresentam variações circadianas que parecem acompanhar o ritmo da temperatura corporal, o objetivo deste estudo foi comparar a freqüência cardíaca máxima (FCmax) no teste de Bruce (Tbruce) em diferentes horários do dia. Foram estudados 11 indivíduos do gênero masculino, com 22,0 ± 1,6 anos, fisicamente ativos e do cronotipo intermediário. Observaram-se FC de repouso (FCrep), FC máxima (FCmax), percepção de esforço (PE) e tempo até a exaustão (TBruce). Para medir a FC, foi utilizado o cardiofreqüencímetro Polar Vantage NV. A PE foi obtida pela escala de Borg (6-20). Aplicou-se o protocolo de Bruce para esteira ergométrica, até a exaustão, em seis horários distintos 900, 1200, 1500, 1800, 2100 e 2400 horas. Os resultados foram submetidos à análise de variância para medidas repetidas, seguida do teste de Tukey (p < 0,05) e ao ajuste Cosinor para identificação de padrões rítmicos. Houve diferença significativa entre a FCrep das 1500 e 2400 horas (67,2 ± 6,9 e 60,4 ± 6,4bpm) e na FCmax das 1200 e 2400 horas (197,4 ± 7,9 e 191,3 ± 5,8bpm). Não foi observada diferença na PE e no TBruce. Foi encontrada ritmicidade em um indivíduo na FCrep, um na FCmax e dois no TBruce. Concluiu-se que, em condições não controladas, mantendo-se as atividades diárias, tanto a FCrep quanto a Fcmax apresentam valores mais baixos por volta das 2400 horas, sem perda no desempenho aeróbio máximo e sem alteração da PE. Esses achados devem ser considerados na avaliação aeróbia e na prescrição de exercícios em horários mais tardios.
ABSTRACT
The aim of this study was to compare the maximal heart rate (HRmax) in the Bruce test (TBruce) at different times of the day, since several measurements of the human performance present circadian variations which seem to follow the body temperature rhythm. Eleven male individuals, with 22.0 ± 1.6 years, physically active and from the intermediate chronotype were studied. The resting HR (HRres), maximal HR (HRmax), perceived exertion (PE) and time until exhaustion (TBruce) were observed. The Polar Vantage NV cardiofrequencymeter was used in order to measure the HR. The PE was obtained through the Borg's scale (6-20). The protocol by Bruce for treadmill was applied until exhaustion, at 6 different times 900; 1200; 1500; 1800; 2100 and 2400 hours. The results were submitted to the variance analysis for repeated measurements, followed by Tukey test (p < 0.05) and the Cosinor adjustment for identification of rhythmic patterns. There was significant difference between the HRres of the 1500 and 2400 h (67.2 ± 6.9 and 60.4 bpm) and in the HR max of the 1200 and 2400 hours (197.4 ± 7.9 and 191.3 ± 5.8 bpm). No difference was identified in the PE and in the TBruce. Rhythmicity was found in 1 individual in the HRres, 1 in the HRmax and 2 in the TBruce. It was concluded that in uncontrolled conditions, whenever daily activities are kept, both HRres and HRmax present lower indices around 2400 hours, with no loss in the maximal aerobic performance and no PE alteration. These findings should be considered in the aerobic evaluation and in the exercises prescription at later times.
RESUMEN
Debido a que muchas medidas de desempeño humano presentan variaciones circadianas que parecen acompañar el ritmo de la temperatura corporal, el objetivo de este estudio ha sido el de comparar la frecuencia cardíaca máxima (FCmax) en el test de Bruce (TBruce) en diferentes horarios del día. Fueron estudiados 11 individuos del género masculino, con 22,0 ± 1,6 años, físicamente activos y de cronotipo intermedio. Se observó la FC de reposo (FCrep), FC máxima (FCmax), percepción de esfuerzo (PE) y tiempo hasta la extenuación (TBruce). Para medir la FC se usó el cardiofrecuencímetro Polar Vantage NV. La PE se obtuvo por la escala de Borg (6-20). Se aplicó el protocolo de Bruce para cinta ergométrica, hasta la extenuación, en 6 horarios distintos 900, 1200, 1500, 1800, 2100 y 2400 horas. Los resultados fueron sometidos a análisis de varianza para medidas repetidas, seguida del test de Tukey (p < 0,05) y al ajuste Cosinor para identificación de los padrones rítmicos. Hubo diferencia significativa entre la FCrep de las 1500 y 2400 h (67,2 ± 6,9 y 60,4 ± 6,4 bpm) y en la FCmax de las 1200 y 2400 horas (197,4 ± 7,9 y 191,3 ± 5,8 bpm). No fue observada diferencia en la PE y en el TBruce. Se encontró ritmo en 1 individuo en la FCrep, 1 en la FCmax y 2 en el TBruce. A partir de esto se concluyó que, en condiciones no controladas, manteniéndose las actividades diarias, tanto la FCrep, como la Fcmax, presentan valores más bajos alrededor de las 2400 horas, sin pérdida en el desempeño aeróbico máximo y sin alteración de PE. Estos resultados deben ser considerados en la evaluación aeróbica y en la prescripción de ejercicios en horarios más tardíos.
Subject(s)
Full text: Available Index: LILACS (Americas) Main subject: Running / Time Factors / Anaerobic Threshold / Analysis of Variance / Muscle Fatigue / Exercise Test / Heart Rate Type of study: Prognostic study / Screening study Limits: Humans / Male Language: Portuguese Journal: Rev. bras. med. esporte Journal subject: Sports Medicine Year: 2006 Type: Article Affiliation country: Brazil Institution/Affiliation country: Universidade Bandeirante de São Paulo/BR / Universidade Federal de Juiz de Fora/BR / Universidade de São Paulo/BR

Similar

MEDLINE

...
LILACS

LIS

Full text: Available Index: LILACS (Americas) Main subject: Running / Time Factors / Anaerobic Threshold / Analysis of Variance / Muscle Fatigue / Exercise Test / Heart Rate Type of study: Prognostic study / Screening study Limits: Humans / Male Language: Portuguese Journal: Rev. bras. med. esporte Journal subject: Sports Medicine Year: 2006 Type: Article Affiliation country: Brazil Institution/Affiliation country: Universidade Bandeirante de São Paulo/BR / Universidade Federal de Juiz de Fora/BR / Universidade de São Paulo/BR