Your browser doesn't support javascript.
loading
Punção aspirativa por agulha fina: desempenho no diagnóstico diferencial de nódulos mamários palpáveis / Fine needle aspiration biopsy: performance in the differential diagnosis of palpable breast masses
Almeida, Orlando José de; Alvarenga, Marcelo; Cecatti, José Guilherme; Jorge, Jessé de Paula Neves; Tambascia, Júlia Kawamura.
  • Almeida, Orlando José de; s.af
  • Alvarenga, Marcelo; s.af
  • Cecatti, José Guilherme; s.af
  • Jorge, Jessé de Paula Neves; s.af
  • Tambascia, Júlia Kawamura; s.af
Rev. bras. ginecol. obstet ; 20(8): 463-467, set. 1998. tab
Article in Portuguese | LILACS | ID: lil-454281
RESUMO

Objetivo:

avaliar, de forma prospectiva, o desempenho da punção aspirativa por agulha fina (PAAF) no diagnóstico diferencial de nódulos mamários palpáveis.

Método:

avaliaram-se a sensibilidade, a especificidade, os valores preditivos e a acurácia deste teste em 102 mulheres com idade superior a 30 anos, com nódulos mamários palpáveis, atendidas na Universidade Estadual de Campinas. As punções foram realizadas por um único examinador.

Resultados:

o procedimento teve sensibilidade de 97 por cento, especificidade de 87 por cento, valor preditivo positivo de 94 por cento e negativo de 93 por cento. A taxa de material insuficiente ou insatisfatório foi de 16 por cento na primeira punção, diminuindo para 2 por cento com uma nova PAAF.

Conclusões:

Este teste mostrou-se altamente sensível e específico no diagnóstico diferencial de nódulos mamários palpáveis, reafirmando-se a sua grande importância na abordagem clínica de nódulos palpáveis.
ABSTRACT

Purpose:

to evaluate, in a prospective way, the performance of the fine needle aspiration biopsy in the differential diagnosis of palpable breast masses.

Method:

the sensitivity, specificity, positive and negative predictive values for this test were evaluated in 102 women with age above 30 years and a palpable breast mass, who were attended at the University of Campinas. All punctures were performed by the same examiner.

Results:

the procedure had a sensitivity of 97 percent, specificity of 87 percent, positive predictive value of 94 percent and negative predictive value of 93 percent. The insufficient or unsatisfactory sample rate was 16 percent for the first aspiration, decreasing to 2 percent with a new procedure.

Conclusions:

this test showed to be highly sensitive and specific for the differential diagnosis of palpable breast masses, reassuring its great importance for the clinical approach of palpable masses.
Subject(s)
Full text: Available Index: LILACS (Americas) Main subject: Breast Neoplasms Type of study: Diagnostic study Limits: Female / Humans Language: Portuguese Journal: Rev. bras. ginecol. obstet Journal subject: Gynecology / Obstetrics Year: 1998 Type: Article

Similar

MEDLINE

...
LILACS

LIS

Full text: Available Index: LILACS (Americas) Main subject: Breast Neoplasms Type of study: Diagnostic study Limits: Female / Humans Language: Portuguese Journal: Rev. bras. ginecol. obstet Journal subject: Gynecology / Obstetrics Year: 1998 Type: Article