Your browser doesn't support javascript.
loading
Comportamento da impedância elétrica dos tecidos biológicos durante estimulação elétrica transcutânea / Electrical impedance behavior of biological tissues during transcutaneous electrical stimulation
Bolfe, V. J; Ribas, S. I; Montebelo, M. I. L; Guirro, R. R. J.
  • Bolfe, V. J; Universidade Metodista de Piracicaba. Programa de Pós-Graduação em Fisioterapia. Piracicaba. BR
  • Ribas, S. I; Universidade Metodista de Piracicaba. Programa de Pós-Graduação em Fisioterapia. Piracicaba. BR
  • Montebelo, M. I. L; Universidade Metodista de Piracicaba. Programa de Pós-Graduação em Fisioterapia. Piracicaba. BR
  • Guirro, R. R. J; Universidade Metodista de Piracicaba. Programa de Pós-Graduação em Fisioterapia. Piracicaba. BR
Braz. j. phys. ther. (Impr.) ; 11(2): 153-159, mar.-abr. 2007. ilus
Article in Portuguese | LILACS | ID: lil-458021
RESUMO
OBJETIVO: Analisar a impedância elétrica dos tecidos biológicos durante estimulação elétrica em diferentes segmentos, faces e freqüências da corrente, aumentando-se a distância intereletrodos. MÉTODO: 20 voluntárias, idade média 23 ± 2,25anos e índice de massa corporal 20,65 ± 1,44kg/m², permaneceram em decúbito, sendo um eletrodo posicionado proximalmente às interlinhas articulares do punho e tornozelo, anterior e posteriormente, ou à espinha ilíaca póstero-superior, e outro eletrodo distanciado seqüencialmente em 10, 20, 30 e 40cm. Foram aplicadas duas correntes (100us e 10mA), uma de 100Hz (BF) e outra de 2000Hz modulada em 100 por cento da amplitude para 100Hz (MF), com intervalo mínimo de 7 dias. A impedância foi calculada, indiretamente, pela Lei de Ohm, a partir da intensidade aplicada e da tensão elétrica captada em sistema composto por osciloscópio digital (TDS 210, Tektronix®) e gerador de corrente constante (Dualpex 961, Quark®). Para análise estatística, aplicou-se Anova-F e Kruskal-Wallis com post hoc (SNK), teste de Friedman e coeficiente de correlação de Spearman, considerando p< 0,05. RESULTADOS: Apesar de o comportamento da impedância elétrica com o aumento da distância intereletrodos ser similar para ambas as correntes, houve uma redução da impedância sob estimulação com MF. Nos membros, aproximadamente 50 por cento da variabilidade da impedância é explicada pelo afastamento dos eletrodos, relação essa não observada na face posterior do tronco. Independente do tipo de corrente, o tronco apresentou os menores valores de impedância elétrica, seguido pelo membro inferior. CONCLUSÕES: A impedância elétrica dos tecidos sofre influência da freqüência da corrente e da localização e distância intereletrodos, apresentando padrão não uniforme nos diferentes segmentos.
ABSTRACT
OBJECTIVE: To analyze the electrical impedance of biological tissues during electrical stimulation in relation to different segments, surfaces and current frequencies, with increasing distance between electrodes. METHOD: 20 female volunteers of mean age 23 ± 2.25 years and mean body mass index 20.65 ± 1.44 kg/m² were positioned in decubitus with one electrode placed proximally to the wrist and ankle joint lines, anteriorly and posteriorly, or on the posterosuperior iliac spine, and the other electrode was placed at distance of 10, 20, 30 and 40 cm, sequentially. Two currents (100 us and 10 mA) were applied: one at 100 Hz (LF) and the other at 2000 Hz modulated at 100 percent of the amplitude for 100 Hz (MF), with a minimum interval of seven days. The impedance was calculated indirectly using Ohm's Law, from the applied intensity and the electrical voltage picked up by a system consisting of a digital oscilloscope (TDS 210, Tektronix®) and a direct current generator (Dualpex 961, Quark®). For statistical analysis, Anova-F and Kruskal-Wallis were applied, with post hoc (SNK), Friedman test and Spearman correlation coefficient, taking p< 0.05. RESULTS: Despite similar electrical impedance behavior with increasing distance between electrodes for the two currents, there was a reduction in impedance under MF stimulation. In the limbs, approximately 50 percent of the impedance variance was explained by the increase in electrode separation, although this relationship was not observed on the posterior surface of the trunk. Independent of the current type, the trunk presented the lowest electrical impedance, followed by the lower limbs. CONCLUSION: The electrical impedance of the tissues was influenced by current frequency and the positioning and distance between electrodes, thus presenting a non-uniform pattern in the different segments.
Subject(s)
Full text: Available Index: LILACS (Americas) Main subject: Cells / Electric Impedance / Electric Stimulation Limits: Female / Humans Language: Portuguese Journal: Braz. j. phys. ther. (Impr.) Journal subject: MEDICINA FISICA E REABILITACAO Year: 2007 Type: Article Affiliation country: Brazil Institution/Affiliation country: Universidade Metodista de Piracicaba/BR

Similar

MEDLINE

...
LILACS

LIS

Full text: Available Index: LILACS (Americas) Main subject: Cells / Electric Impedance / Electric Stimulation Limits: Female / Humans Language: Portuguese Journal: Braz. j. phys. ther. (Impr.) Journal subject: MEDICINA FISICA E REABILITACAO Year: 2007 Type: Article Affiliation country: Brazil Institution/Affiliation country: Universidade Metodista de Piracicaba/BR