Comparação dos valores do índice bispectral em pacientes com paralisia cerebral em estado de vigília / Comparison of the bispectral index in awake patients with cerebral palsy
Costa, Verônica Vieira da; Torres, Rafael Villela S. D; Arci, Érika Carvalho Pires; Saraiva, Renato Ângelo.
  • Costa, Verônica Vieira da; Hospital Sarah. Brasília. BR
  • Torres, Rafael Villela S. D; Hospital Sarah. Brasília. BR
  • Arci, Érika Carvalho Pires; Hospital Sarah. Brasília. BR
  • Saraiva, Renato Ângelo; Rede Sarah de Hospitais. Brasília. BR
Rev. bras. anestesiol ; 57(4): 382-390, jul.-ago. 2007. tab
Article in Portuguese | LILACS | ID: lil-458056
RESUMO
JUSTIFICATIVA E

OBJETIVOS:

O EEG-BIS foi criado por meio de estudos em pacientes adultos saudáveis e as primeiras publicações em crianças surgiram a partir de 1998. A paralisia cerebral (PC) é secundária à lesão estática do encéfalo em desenvolvimento. A necessidade de realização de exames e procedimentos cirúrgicos para correção de deformidades sob anestesia ou sedação é comum nesses pacientes. Torna-se cada vez mais necessária a monitorização do estado de hipnose do paciente anestesiado e pode-se incluir nesse grupo os pacientes com paralisia cerebral. O objetivo desse estudo foi avaliar a eficiência do EEG-BIS nos pacientes com paralisia cerebral (PC) em comparação com os pacientes sem doenças neurológicas (sem PC), em estado de vigília.

MÉTODO:

Foram avaliados dois grupos de pacientes um com diagnóstico de paralisia cerebral e outro sem doença do sistema nervoso central (SNC). Na véspera da intervenção cirúrgica, na enfermaria, junto aos pacientes despertos era colocado o monitor de EEG-BIS e solicitado que fechassem os olhos. Os valores que apareciam na tela do monitor, em um intervalo de 10 minutos, eram anotados e registrados em ficha padronizada, sendo calculado um valor médio por paciente.

RESULTADOS:

Foram avaliados 188 pacientes, de ambos os sexos, com idade média de 10, 07 ± 2,9 (PC) e 10,21 ± 3,1 (sem PC) anos. O grupo PC apresentou EEG-BIS basal de 95,83 ± 5,142 e o grupo sem PC de 96,56 ± 1,941 sem haver diferença estatística significativa entre eles.

CONCLUSÕES:

Os sinais de EEG são captados normalmente e os valores de EEG-BIS dos pacientes com PC são semelhantes ao dos pacientes sem PC no estado de vigília.
ABSTRACT
BACKGROUND AND

OBJECTIVES:

The EEG-BIS was created after studies in healthy adult subjects, and studies in children were first published in 1998. Cerebral palsy (CP) is secondary to a static lesion of the developing brain. The need to perform exams and surgical procedures to correct deformities, under anesthesia or sedation, is common in these patients. The need for monitoring of the hypnotic state in anesthetized patients has increased; patients with cerebral palsy can be included in this group of patients. The objective of this study was to evaluate the efficacy of the awake EEG-BIS in patients with cerebral palsy (CP) by comparing it with patients without neurological disorders (without CP).

METHODS:

Two groups of patients were evaluated one composed of patients with the diagnosis of cerebral palsy, and the other with subjects without central nervous system (CNS) disorders. The day before the surgery, hospitalized patients were connected to the EEG-BIS monitor and were asked to close their eyes. The values on the monitor were recorded at 10-minute intervals on a standard form, and the mean value for each patient was calculated.

RESULTS:

One hundred and eighty-eight patients of both genders, mean age of 10.07 ± 2.9 (CP) and 10.21 ± 3.1 (without CP), were evaluated. The basal EEG-BIS of the PC group was 95.83 ± 5.142 and in the non-CP group was 96.56 ± 1.941, which did not demonstrate a statistically significant difference.

CONCLUSIONS:

The signals of the EEG are captured normally and the values of the awake EEG-BIS of CP patients are similar to that of non-CP patients.
RESUMEN
JUSTIFICATIVA Y

OBJETIVOS:

El EEG-BIS fue creado a través de estudios en pacientes adultos saludables y las primeras publicaciones en niños surgieron a partir de 1998. La parálisis cerebral (PC) es secundaria a la lesión estática del encéfalo en desarrollo. La necesidad de realización de exámenes y procedimientos quirúrgicos para la corrección de deformidades bajo anestesia o sedación es común en esos pacientes. Cada vez más se hace necesaria la monitorización del estado de hipnosis del paciente anestesiado y podemos incluir en ese grupo los pacientes con parálisis cerebral. El objetivo de este estudio fue evaluar la eficiencia del EEG-BIS en los pacientes con parálisis cerebral (PC) en comparación con los pacientes sin enfermedades neurológicas (sin PC), en estado de vigilia.

MÉTODO:

Fueron evaluados 2 grupos de pacientes uno con diagnóstico de parálisis cerebral y otro sin enfermedad del sistema nervioso central (SNC). A la víspera de la intervención, en la enfermería, con los pacientes despiertos era colocado el monitor de EEG-BIS y solicitado que cerrasen los ojos. Los valores que aparecían en la pantalla del monitor, en un intervalo de 10 minutos, eran anotados y registrados en ficha estandarizada, siendo calculado un valor promedio por paciente.

RESULTADOS:

Fueron evaluados 188 pacientes, de ambos sexos, con edad promedio de 10, 07 ± 2,9 (PC) y 10,21 ± 3,1 (sin PC) años. El grupo PC presentó EEG-BIS basal de 95,83 ± 5,142 y el grupo sin PC de 96,56 ± 1,941 sin haber una diferencia estadística significativa entre ellos.

CONCLUSIONES:

Las señales de EEG se captan normalmente y los valores de EEG-BIS de los pacientes con PC son semejantes a los de los s pacientes sin PC en estado de vigilia.
Subject(s)
Full text: Available Index: LILACS (Americas) Main subject: Cerebral Palsy / Environmental Monitoring / Electroencephalography Limits: Adolescent / Child / Female / Humans / Male Language: Portuguese Journal: Rev. bras. anestesiol Journal subject: Anesthesiology Year: 2007 Type: Article Affiliation country: Brazil Institution/Affiliation country: Hospital Sarah/BR / Rede Sarah de Hospitais/BR

Similar

MEDLINE

...
LILACS

LIS

Full text: Available Index: LILACS (Americas) Main subject: Cerebral Palsy / Environmental Monitoring / Electroencephalography Limits: Adolescent / Child / Female / Humans / Male Language: Portuguese Journal: Rev. bras. anestesiol Journal subject: Anesthesiology Year: 2007 Type: Article Affiliation country: Brazil Institution/Affiliation country: Hospital Sarah/BR / Rede Sarah de Hospitais/BR