Simulação computadorizada do perfil facial em cirurgia ortognática: precisão cefalométrica e avaliação por ortodontistas / Prediction of soft-tissue profile by video imaging in orthognathic surgery: cephalometric accuracy and orthodontists' judgement
Motta, Alexandre Trindade Simões da; Brunharo, Ione Helena Portela; Miguel, José Augusto Mendes; Capelli Júnior, Jonas; Medeiros, Paulo José D'Albuquerque; Almeida, Marco Antonio de Oliveira.
  • Motta, Alexandre Trindade Simões da; Universidade do Estado do Rio de Janeiro. Rio de Janeiro. BR
  • Brunharo, Ione Helena Portela; Universidade do Estado do Rio de Janeiro. Rio de Janeiro. BR
  • Miguel, José Augusto Mendes; Universidade do Estado do Rio de Janeiro. Rio de Janeiro. BR
  • Capelli Júnior, Jonas; Universidade do Estado do Rio de Janeiro. Rio de Janeiro. BR
  • Medeiros, Paulo José D'Albuquerque; Universidade do Estado do Rio de Janeiro. Rio de Janeiro. BR
  • Almeida, Marco Antonio de Oliveira; Universidade do Estado do Rio de Janeiro. Rio de Janeiro. BR
Rev. dent. press ortodon. ortopedi. facial ; 12(5): 71-84, set.-out. 2007. ilus, tab
Article in Portuguese | LILACS | ID: lil-465907
RESUMO

OBJETIVO:

verificar a precisão de um programa de simulação computadorizada na predição de alterações no perfil facial em diferentes tipos de cirurgia ortognática.

METODOLOGIA:

utilizou-se radiografias e fotografias de perfil das fases pré-cirúrgica e final de 32 pacientes. As movimentações esqueléticas do procedimento cirúrgico foram reproduzidas no traçado pré-cirúrgico, gerando mudanças no perfil mole, originando o traçado e a imagem predictiva de perfil. Analisou-se o perfil da amostra total e dividida em dois grupos, sem cirurgias no sentido vertical (AP) e com cirurgias de impacção ou reposicionamento inferior da maxila (V). Comparou-se cefalometricamente pontos do perfil mole dos traçados predictivo e final. As imagens predictivas computadorizadas foram comparadas com as imagens finais por 20 ortodontistas, que avaliaram cinco regiões perfil total, nariz, lábio superior, lábio inferior e mento. RESULTADOS E

CONCLUSÕES:

observou-se variabilidade de posicionamento dos pontos do perfil, com mais de 60 por cento dos erros até 2mm e 17 por cento acima de 3mm. Diferenças significativas entre os pontos foram mais freqüentes no sentido vertical. Os ângulos nasolabial e mentolabial predictivos apresentaram-se mais agudos que os finais. As notas médias encontradas na análise subjetiva variaram de 56 para o lábio inferior a 75,42 para o nariz. As imagens predictivas não apresentaram diferenças significativas de qualidade entre os grupos. Em comparação com outros sistemas de simulação computadorizada, este programa pode ser considerado útil na prática clínica ortodôntica e cirúrgica. Entretanto, diante de algumas limitações observadas, recomenda-se cautela no planejamento e apresentação do caso, considerando que algumas predições podem exigir melhorias com ferramentas de ajuste.
ABSTRACT

AIM:

To verify the accuracy of a video imaging software on the soft tissue profile prediction of patients who underwent different types of orthognathic surgery.

METHODS:

Presurgical and posttreatment lateral cephalograms and photographs of 32 patients were used. Profile predictions were obtained from hard tissue manipulation on the presurgical tracings. Prediction evaluation was applied to the total sample and to subgroups with maxillary impaction or downgraft (V) or without surgeries in the vertical plane (AP). Points of prediction's soft tissue line were compared with those of the posttreatment tracing. Prediction and posttreatment profile images were subjectively compared by 20 orthodontists. Five regions (overall profile, nose, upper lip, lower lip and chin) were graded from 0 to 100 with a visual analog scale. RESULTS AND

CONCLUSIONS:

Soft-tissue profile points showed location variability, with more than 60 percent of the errors up to 2mm and 17 percent greater than 3mm. Statistically significant differences in the cephalometric analysis were more frequently observed on the vertical plane. Nasolabial and mentolabial prediction angles were more acute than those of the posttreatment tracings. The aesthetic analysis showed greater mean values in comparison with other studies, varying from 56.00 for the lower lip to 75.42 for the nose. Prediction images precision showed no significant difference between cases with or without vertical changes. This program can be considered useful in orthodontic and surgical clinical practice. However, based on some observed limitations, the authors recommend caution in treatment planning and case presentation, and some predictions may require improvement with enhancement tools.
Subject(s)

Full text: Available Index: LILACS (Americas) Main subject: Surgery, Oral / Cephalometry / Diagnosis, Computer-Assisted / Face Type of study: Diagnostic study / Prognostic study / Risk factors Limits: Adult / Female / Humans / Male Language: Portuguese Journal: Rev. dent. press ortodon. ortopedi. facial Year: 2007 Type: Article Affiliation country: Brazil Institution/Affiliation country: Universidade do Estado do Rio de Janeiro/BR

Similar

MEDLINE

...
LILACS

LIS

Full text: Available Index: LILACS (Americas) Main subject: Surgery, Oral / Cephalometry / Diagnosis, Computer-Assisted / Face Type of study: Diagnostic study / Prognostic study / Risk factors Limits: Adult / Female / Humans / Male Language: Portuguese Journal: Rev. dent. press ortodon. ortopedi. facial Year: 2007 Type: Article Affiliation country: Brazil Institution/Affiliation country: Universidade do Estado do Rio de Janeiro/BR