Your browser doesn't support javascript.
loading
Extrusão dos implantes em portadores de cavidade anoftálmica / Anophthalmic cavity and implant extrusion
Schellini, Silvana Artioli; Ichida, Flavia Keiko; Padovani, Carlos Roberto.
  • Schellini, Silvana Artioli; Universidade Estadual Paulista 'Julio Mesquita Filho'. Faculdade de Medicina de Botucatu. Departamento de Oftalmologia, Otorrinolaringologia e Cirurgia de Cabeça e Pescoço. Botucatu. BR
  • Ichida, Flavia Keiko; Universidade Estadual Paulista 'Julio Mesquita Filho'. Faculdade de Medicina de Botucatu. Departamento de Oftalmologia, Otorrinolaringologia e Cirurgia de Cabeça e Pescoço. Botucatu. BR
  • Padovani, Carlos Roberto; Universidade Estadual Paulista 'Julio Mesquita Filho'. Instituto de Biociências. Departamento de Bioestatística. Botucatu. BR
Arq. bras. oftalmol ; 70(5): 752-755, set.-out. 2007. tab
Article in Portuguese | LILACS | ID: lil-470089
RESUMO

OBJETIVO:

Avaliar as características dos portadores de cavidades anoftálmicas que desenvolveram extrusão do implante.

MÉTODOS:

Estudo retrospectivo, observacional, tendo sido avaliados 37 portadores de cavidade anoftálmica que tiveram extrusão do implante de cavidade, na Faculdade de Medicina de Botucatu-UNESP.

RESULTADOS:

As extrusões ocorreram em cavidades enucleadas ou evisceradas, a maioria delas submetidas a cirurgia em decorrência de phthisis bulbi ou trauma, em geral de 1 a 2 anos após a cirurgia inicial. A deiscência precedeu a extrusão em todos os casos, tendo a extrusão ocorrido com todos os tipos de implantes empregados.

CONCLUSÃO:

Após a colocação de implantes de cavidade podem ocorrer complicações. A deiscência e extrusão das esferas são possibilidades que podem requerer nova intervenção cirúrgica, para a qual o paciente e o oftalmologista devem estar preparados.
ABSTRACT

PURPOSE:

To evaluate the characteristics of patients with anophthalmic cavity who developed sphere extrusion.

METHODS:

A retrospective observational study was done evaluating 37 patients with anophthalmic cavity and sphere extrusion at the "Faculdade de Medicina de Botucatu-UNESP".

RESULTS:

Extrusion was observed in enucleated and eviscerated cavities. The majority of the patients had the eye removed because of phthisis bulbi or trauma and the extrusion happened 1 or 2 years after the surgery. Extrusion was preceded by conjunctival dehiscence and exposure of the sphere and occurred with all used implants.

CONCLUSION:

Complications after orbital implant placement are a possibility. Dehiscence and sphere extrusion may happen and another surgery would be necessary. The patient and the ophthalmologist have to be prepared for this.
Subject(s)

Full text: Available Index: LILACS (Americas) Main subject: Eye Enucleation / Foreign-Body Migration / Eye Evisceration / Orbital Implants Type of study: Observational study / Risk factors Limits: Adolescent / Adult / Aged / Aged80 / Child / Child, preschool / Female / Humans / Male Language: Portuguese Journal: Arq. bras. oftalmol Journal subject: Ophthalmology Year: 2007 Type: Article Affiliation country: Brazil Institution/Affiliation country: Universidade Estadual Paulista 'Julio Mesquita Filho'/BR

Similar

MEDLINE

...
LILACS

LIS

Full text: Available Index: LILACS (Americas) Main subject: Eye Enucleation / Foreign-Body Migration / Eye Evisceration / Orbital Implants Type of study: Observational study / Risk factors Limits: Adolescent / Adult / Aged / Aged80 / Child / Child, preschool / Female / Humans / Male Language: Portuguese Journal: Arq. bras. oftalmol Journal subject: Ophthalmology Year: 2007 Type: Article Affiliation country: Brazil Institution/Affiliation country: Universidade Estadual Paulista 'Julio Mesquita Filho'/BR