Your browser doesn't support javascript.
loading
Revision of the Sokolow-Lyon-Rappaport and cornell voltage criteria for left ventricular hypertrophy / Revisão dos critérios de Sokolow-Lyon-Rappaport e cornell para hipertrofia do ventrículo esquerdo
Rodrigues, Sérgio Lamêgo; D'Angelo, Lílian; Pereira, Alexandre Costa; Krieger, José Eduardo; Mill, José Geraldo.
  • Rodrigues, Sérgio Lamêgo; Universidade Federal do Espírito Santo. Centro de Ciências da Saúde. Vitória. BR
  • D'Angelo, Lílian; Universidade Federal do Espírito Santo. Centro de Ciências da Saúde. Vitória. BR
  • Pereira, Alexandre Costa; USP. FM. Hospital das Clínicas. Instituto do Coração. São Paulo. BR
  • Krieger, José Eduardo; USP. FM. Hospital das Clínicas. Instituto do Coração. São Paulo. BR
  • Mill, José Geraldo; Universidade Federal do Espírito Santo. Centro de Ciências da Saúde. Vitória. BR
Arq. bras. cardiol ; 90(1): 46-53, jan. 2008. ilus, tab
Article in English, Portuguese | LILACS | ID: lil-476045
RESUMO
FUNDAMENTO A hipertrofia do ventrículo esquerdo (HVE) detectada pela eletrocardiografia é um forte preditor de morbidade e mortalidade cardiovasculares.

OBJETIVO:

Analisar o desempenho dos critérios de Sokolow-Lyon-Rappaport (SLR) e de Cornell, em amostra populacional, em relação ao diagnóstico de HVE à ecocardiografia.

MÉTODOS:

Entre os 682 participantes da segunda fase do Projeto MONICA-OMS/Vitória, 641 foram avaliados por meio de eletrocardiografia e ecocardiografia. O subgrupo de indivíduos saudáveis (n = 269) foi usado para gerar valores de referência da massa do ventrículo esquerdo (MVE). As sensibilidades e especificidades dos critérios eletrocardiográficos foram determinadas pela curva ROC (receptor-operator characteristics) em relação ao diagnóstico de HVE definido pelo critério ecocardiográfico interno (MVE > 48 g/m2,7 e 46 g/m2,7 para homens e mulheres, respectivamente).

RESULTADOS:

A prevalência de HVE à ecocardiografia foi de 23,7 por cento na amostra global, em que havia 49 por cento de hipertensos. O critério de Cornell apresentou melhor associação com a MVE estimada pela ecocardiografia (r = 0,37; p < 0,01) que o critério de SLR (r = 0,19), além de melhor desempenho na análise da área sob a curva ROC. Os novos pontos de corte para o critério de Cornell definidos internamente (2,3 mV para homens e 1,9 mV para mulheres) apresentaram combinação aceitável de sensibilidade para homens e mulheres (22,5 por cento e 28 por cento, respectivamente), com alta especificidade (95 por cento).

CONCLUSÃO:

Os critérios clássicos de SLR e Cornell apresentaram baixo desempenho em relação à HVE definida pela ecocardiografia. Entretanto, a acurácia pode ser melhorada, utilizando-se os critérios de Cornell definidos neste estudo.
ABSTRACT

BACKGROUND:

Electrocardiographically-detected left ventricular hypertrophy (LVH) is a strong predictor of cardiovascular morbidity and mortality.

OBJECTIVE:

To assess the performance of the Sokolow-Lyon-Rappaport (SLR) and Cornell voltage criteria in a population sample regarding the diagnosis of LVH on echocardiogram (ECHO).

METHODS:

A total of 641 out of the 682 participants of the second phase of the MONICA-Vitória project were assessed using electrocardiogram and echocardiogram. A subgroup of healthy individuals (n=269) was used to generate reference values of LV mass (LVM). Sensitivities and specificities of the electrocardiographic criteria were determined by the ROC (receptor-operator characteristics) curve in relation to the diagnosis of LVH, as defined by the internal echocardiographic criterion (LVM > 48 and 46 g/m2.7 for males and females, respectively).

RESULTS:

The prevalence of LVH as detected by ECHO was 23.7 percent in the total sample, in which 49 percent of the individuals were hypertensive. The Cornell criterion showed a better association with the LVM as estimated by ECHO (r= 0.37, p < 0.01) than the SLR criterion (r= 0.19) as well as a better performance in the analysis of the area under the ROC curve. The new cut-off points for the internally-defined Cornell voltage criterion (2.3 mV for males and 1.9 mV for females) showed an acceptable combination of sensitivity (22.5 and 28 percent for males and females, respectively), with a high specificity (95 percent). CONLUSION The classic SLR and Cornell voltage criteria showed a low performance in relation to LVH as detected by the ECHO. However, this accuracy may be improved by using the Cornell voltage criteria defined in the present study.
Subject(s)

Full text: Available Index: LILACS (Americas) Main subject: Echocardiography / Hypertrophy, Left Ventricular / Electrocardiography Type of study: Diagnostic study / Etiology study / Prognostic study / Risk factors Limits: Adult / Aged / Female / Humans / Male Language: English / Portuguese Journal: Arq. bras. cardiol Journal subject: Cardiology Year: 2008 Type: Article Affiliation country: Brazil Institution/Affiliation country: USP/BR / Universidade Federal do Espírito Santo/BR

Similar

MEDLINE

...
LILACS

LIS

Full text: Available Index: LILACS (Americas) Main subject: Echocardiography / Hypertrophy, Left Ventricular / Electrocardiography Type of study: Diagnostic study / Etiology study / Prognostic study / Risk factors Limits: Adult / Aged / Female / Humans / Male Language: English / Portuguese Journal: Arq. bras. cardiol Journal subject: Cardiology Year: 2008 Type: Article Affiliation country: Brazil Institution/Affiliation country: USP/BR / Universidade Federal do Espírito Santo/BR