Your browser doesn't support javascript.
loading
Contribuição da tomografia computadorizada em pacientes com metástases pulmonares de carcinoma diferenciado de tireóide não-aparentes na radiografia e tratados com radioiodo / Contribution of computed tomography in patients with lung metastases of differentiated thyroid carcinoma not apparent on plain radiography who were treated with radioiodine
Rosário, Pedro W. S; Tavares, Wilson C; Barroso, Álvaro L; Rezende, Leonardo L; Padrão, Eduardo L; Purisch, Saulo.
  • Rosário, Pedro W. S; Santa Casa Belo Horizonte. Serviço de Endocrinologia. Departamento de Tireóide. Belo Horizonte. BR
  • Tavares, Wilson C; Instituto Alpha de Gastroenterologia. Belo Horizonte. BR
  • Barroso, Álvaro L; Santa Casa Belo Horizonte. Serviço de Medicina Nuclear. Belo Horizonte. BR
  • Rezende, Leonardo L; Santa Casa Belo Horizonte. Serviço de Medicina Nuclear. Belo Horizonte. BR
  • Padrão, Eduardo L; Santa Casa Belo Horizonte. Serviço de Medicina Nuclear. Belo Horizonte. BR
  • Purisch, Saulo; Santa Casa Belo Horizonte. Serviço de Endocrinologia. Departamento de Tireóide. Belo Horizonte. BR
Arq. bras. endocrinol. metab ; 52(1): 114-119, fev. 2008. ilus, tab
Article in Portuguese | LILACS | ID: lil-477440
RESUMO
A tomografia computadorizada (TC) de tórax é mais sensível que a radiografia na detecção de metástases pulmonares do carcinoma diferenciado de tireóide (CDT), sendo importante conhecer melhor o valor agregado desse método. Este estudo avaliou a resposta ao tratamento com 131I em pacientes com metástases pulmonares de CDTs não-aparentes na radiografia e o valor da TC nesses casos. Foram avaliados 25 pacientes com metástases pulmonares não-aparentes na radiografia, que receberam inicialmente 100 a 200 mCi de 131I. Naqueles com pesquisa de corpo inteiro (PCI) pós-dose com captação pulmonar, um novo tratamento era realizado após seis a 12 meses, e assim sucessivamente. A chance do encontro de captação pulmonar na PCI pós-dose não foi diferente em pacientes com TC negativa ou positiva (100 por cento versus 91,5 por cento). Os valores médios de tireoglobulina (Tg) sérica foram maiores naqueles com TC positiva (108 ng/mL versus 52 ng/mL). PCI pós-dose negativa foi alcançada em 82 por cento dos pacientes com TC positiva e em 92,3 por cento com TC negativa, e a atividade acumulada de 131I para alcançar essa resposta não foi diferente nos dois grupos (em média, 300 mCi). Quarenta e sete por cento dos pacientes com TC negativa ao final do tratamento apresentaram Tg estimulada indetectável, mas nenhum daqueles que permaneceu com TC positiva apresentou-a. Em pacientes com Tg elevada, o resultado da TC aparentemente não altera a indicação da terapia e a atividade de 131I a ser administrada. Nos casos com metástases pulmonares, a permanência de micronódulos na TC nos pacientes com PCI pós-dose negativa após o tratamento foi associada à persistência de Tg detectável.
ABSTRACT
Computed tomography (CT or CAT Scan) of the chest is more sensitive than radiography in the detection of lung metastases of differentiated thyroid cancer (DTC), but little information is available regarding the aggregated value of this method. The present study evaluated the response of patients with lung metastases of DTC not apparent on radiography to treatment with 131I and the value of CT in these cases. Twenty-five patients with lung metastases not apparent on radiography, who initially received 100-200 mCi I151, were evaluated and those presenting pulmonary uptake on post-therapy WBS were submitted to a new treatment after 6 to 12 months, and so on. The chance of detection of pulmonary uptake on post-therapy WBS did not differ between patients with negative and positive CT (100 percent versus 91.5 percent). Mean serum Tg levels were higher in patients with positive CT (108 ng/ml versus 52 ng/ml). Negative post-therapy WBS was achieved in 82 percent of patients with positive CT and in 92.3 percent with negative CT and the cumulative I131 activity necessary to achieve this outcome did not differ between the two groups (mean = 300 mCi). Stimulated Tg was undetectable in 47 percent of patients with negative CT at the end of treatment, but in none of the patients whose CT continued to be positive. In patients with elevated Tg, the CT result apparently did not change the indication of therapy or the I131 activity to be administered. In cases with lung metastases, the persistence of micronodules on CT was associated with the persistence of detectable Tg in patients presenting negative post-therapy WBS.
Subject(s)

Full text: Available Index: LILACS (Americas) Main subject: Thyroid Neoplasms / Carcinoma, Papillary / Tomography, X-Ray Computed / Lung Neoplasms Type of study: Observational study / Prognostic study / Risk factors Limits: Adolescent / Adult / Female / Humans / Male Language: Portuguese Journal: Arq. bras. endocrinol. metab Journal subject: Endocrinology / Metabolism Year: 2008 Type: Article Affiliation country: Brazil Institution/Affiliation country: Instituto Alpha de Gastroenterologia/BR / Santa Casa Belo Horizonte/BR

Similar

MEDLINE

...
LILACS

LIS

Full text: Available Index: LILACS (Americas) Main subject: Thyroid Neoplasms / Carcinoma, Papillary / Tomography, X-Ray Computed / Lung Neoplasms Type of study: Observational study / Prognostic study / Risk factors Limits: Adolescent / Adult / Female / Humans / Male Language: Portuguese Journal: Arq. bras. endocrinol. metab Journal subject: Endocrinology / Metabolism Year: 2008 Type: Article Affiliation country: Brazil Institution/Affiliation country: Instituto Alpha de Gastroenterologia/BR / Santa Casa Belo Horizonte/BR