Your browser doesn't support javascript.
loading
Evaluación de dos pruebas rápidas [NOW® ICT Malaria Pf/Pv y OptiMAL®] para el diagnóstico de paludismo en Tumaco, Colombia / Evaluation of two rapid diagnostic tests, NOW® ICT Malaria Pf/Pv and OptiMAL®, for diagnosis of malaria
Mendoza, Nohora Marcela; García, Marisol; Cortés, Liliana Jazmín; Vela, Claudia; Erazo, Rigoberto; Pérez, Pilar; Ospina, Olga Lucía; Burgos, Javier Darío.
  • Mendoza, Nohora Marcela; Instituto Nacional de Salud. Red Nacional de Laboratorios. Grupo de Parasitología. Bogotá. CO
  • García, Marisol; Instituto Nacional de Salud. Red Nacional de Laboratorios. Grupo de Parasitología. Bogotá. CO
  • Cortés, Liliana Jazmín; Instituto Nacional de Salud. Red Nacional de Laboratorios. Grupo de Parasitología. Bogotá. CO
  • Vela, Claudia; Instituto Departamental de Nariño. Pasto. CO
  • Erazo, Rigoberto; Instituto Departamental de Nariño. Pasto. CO
  • Pérez, Pilar; Instituto Departamental de Nariño. Pasto. CO
  • Ospina, Olga Lucía; Instituto Nacional de Salud. Red Nacional de Laboratorios. Grupo de Parasitología. Bogotá. CO
  • Burgos, Javier Darío; Universidad Nacional de Colombia. Instituto de Estudios Ambientales. Bogotá. CO
Biomédica (Bogotá) ; 27(4): 571-580, dic. 2007. tab
Article in Spanish | LILACS | ID: lil-478225
RESUMEN
Introducción. El Instituto Nacional de Salud con el fin de mejorar el acceso al diagnóstico de paludismo, evaluó dos pruebas rápidas para el diagnóstico de dicha enfermedad. Objetivo. Evaluar la sensibilidad, especificidad y concordancia de dos pruebas inmunocromatográficas, NOW® ICT Malaria Pf/Pv y OptiMAL®, frente a la gota gruesa. Materiales y métodos. Se llevó a cabo un estudio descriptivo de concordancia en 214 pacientes de Tumaco, captados mediante búsqueda pasiva y brigadas de atención, que presentaran, por lo menos, uno de los síntomas de la tríada clásica. Resultados. NOW® ICT tuvo una sensibilidad general de 98,4 por ciento (intervalo de confianza de 95 por ciento (IC95 por ciento): 90,3-99,9), especificidad general de 98,0 por ciento (IC95 por ciento: 93,9-99,5). Para Plasmodium falciparum la sensibilidad fue de 98,2 por ciento (IC95 por ciento: 89,4-99,9) especificidad de 98,1 por ciento (IC95 por ciento: 94,1-99,5). Esta sensibilidad disminuyó a 80 por ciento en el rango de 200-4.000 parásitos/µl. Los valores de sensibilidad y especificidad de NOW® ICT para Plasmodium vivax fueron del 100 por ciento y no se afectó la sensibilidad en los rangos de parasitemias establecidos. OptiMAL® tuvo una sensibilidad general de 95,2 por ciento (IC95 por ciento: 85,8-98,8) y especificidad general de 99,3 por ciento (IC95 por ciento: 95,8-100,0). Para P. falciparum OptiMAL® tuvo una sensibilidad de 94,7 por ciento (IC95 por ciento: 84,5-98,6) y especificidad de 99,4 por ciento (IC95 por ciento: 96,0-100,0). La sensibilidad disminuyó a 60 por ciento en el rango de de 200-4.000 parásitos/µl. La sensibilidad de OptiMAL® para P. vivax fue 66,7 por ciento (IC95 por ciento: 24,1-94,0), pero disminuyó a 50 por ciento en el rango de 300-2.500 parásitos/µl. Conclusiones. Se obtuvieron buenos resultados en la sensibilidad y la especificidad para ambas pruebas, pero superiores para NOW® ICT.
ABSTRACT
Introduction. To increase the accessibility of malaria diagnosis, the Instituto Nacional de Salud de Colombia undertook a field trial to evaluate the sensitivity and specificity of two rapid diagnostic tests. Objective. The sensitivity, specificity and concordance was compared for two rapid diagnostic tests for malaria, NOW® ICT Malaria Pf/Pv and OptiMAL®, Materials and methods. A descriptive and concordance study was performed with 214 patients in the southwestern coastal city of Tumaco, Colombia, each of whom presented at least one of the symptoms of the classical malaria triad. Two strategies were applied for patient recruitment—one by passive search and a second through local health brigades. Results. NOW® ICT showed a general sensitivity of 98.4% (95%CI: 90.3-99.9), and a general specificity of 98.0% (95%CI: 93.9-99.5). For Plasmodium falciparum, the sensitivity was 98.2% (95%CI: 89.4-99.9) and the specificity 98.1% (95%CI: 94.1-99.5). The sensitivity was lower (80.0%) when parasitemia ranged from 200 to 4,000 parasites/ ìl. The sensitivity and specificity of the NOW® ICT for P. vivax malaria were 100%. The sensitivity for this test was not affected for the established ranges of parasitemia for P. vivax. The overall figures for OptiMAL® were 95.2% (95%CI: 85.8-98.8) sensitivity and 99.3% (95%CI: 95.8-100.0) specificity. For P. falciparum malaria OptiMAL® showed 94.7% (95%CI: 84.5-98.6) sensitivity and 99.4% (95%CI: 96.0-100.0) specificity. The sensitivity was lower (60.0%) when samples with 200-4,000 parasites/ìl were tested. For P. vivax, OptiMAL® presented a 66.7% (95%CI: 24.1-94.0) sensitivity, which diminished to 50% with a parasitemia between 300-2.500 parasites/ ìL. Conclusions. Good results for sensitivity and specificity were obtained for malaria diagnosis using NOW® ICT and OptiMAL®, with NOW®ICT showing higher sensitivity and specificity values than OptiMAL®.
Subject(s)
Full text: Available Index: LILACS (Americas) Main subject: Plasmodium falciparum / Plasmodium vivax / Malaria Type of study: Diagnostic study Country/Region as subject: South America / Colombia Language: Spanish Journal: Biomédica (Bogotá) Journal subject: Medicine Year: 2007 Type: Article Affiliation country: Colombia Institution/Affiliation country: Instituto Departamental de Nariño/CO / Instituto Nacional de Salud/CO / Universidad Nacional de Colombia/CO

Similar

MEDLINE

...
LILACS

LIS

Full text: Available Index: LILACS (Americas) Main subject: Plasmodium falciparum / Plasmodium vivax / Malaria Type of study: Diagnostic study Country/Region as subject: South America / Colombia Language: Spanish Journal: Biomédica (Bogotá) Journal subject: Medicine Year: 2007 Type: Article Affiliation country: Colombia Institution/Affiliation country: Instituto Departamental de Nariño/CO / Instituto Nacional de Salud/CO / Universidad Nacional de Colombia/CO