Your browser doesn't support javascript.
loading
Reproducibility of the self-controlled six-minute walking test in heart failure patients
Guimarães, Guilherme Veiga; Carvalho, Vitor Oliveira; Bocchi, Edimar Alcides.
  • Guimarães, Guilherme Veiga; Universidade de São Paulo. Faculdade de Medicina. Heart Institute. São Paulo. BR
  • Carvalho, Vitor Oliveira; Universidade de São Paulo. Faculdade de Medicina. Heart Institute. São Paulo. BR
  • Bocchi, Edimar Alcides; Universidade de São Paulo. Faculdade de Medicina. Heart Institute. São Paulo. BR
Clinics ; 63(2): 201-206, 2008. graf, tab
Article in English | LILACS | ID: lil-481049
ABSTRACT

INTRODUCTION:

The six-minute walk test (6WT) has been proposed to be a submaximal test, but could actually demand a high level of exercise intensity from the patient, expressed by a respiratory quotient >1.0, following the guideline recommendations. Standardizing the 6WT using the Borg scale was proposed to make sure that all patients undergo a submaximal walking test.

PURPOSE:

To test the reproducibility of the six-minute treadmill cardiopulmonary walk test (6CWT) using the Borg scale and to make sure that all patients undergo a submaximal test.

METHODS:

Twenty-three male heart failure patients (50±9 years) were included; these patients had both ischemic (5) and non-ischemic (18) heart failure with a left ventricle ejection fraction of 23±7 percent, were diagnosed as functional class NYHA II-III and were undergoing optimized drug therapy. Patients were guided to walk at a pace between "relatively easy and slightly tiring" (11 and 13 on Borg scale). The 6CWT using the Borg scale was performed two times on a treadmill with zero inclination and patient control of speed with an interval of 24 hours. During the sixth minute, we analyzed ventilation (VE, L/min), respiratory quotient, Oxygen consumption (VO2, ml/kg/min), VE/VCO2 slope, heart rate (HR, bpm), systolic blood pressure (SBP, mmHg), diastolic (DBP, mmHg) blood pressure and distance.

RESULTS:

The intraclass correlation coefficients at the sixth minute were HR (r i=0.96, p<0.0001), VE (r i=0.84, p<0.0001), SBP (r i=0.72, p=0.001), distance (r i=0.88, p<0.0001), VO2 (r i=0.92, p<0.0001), SlopeVE/VCO2 (r i=0.86, p<0.0001) and RQ<1 (r i=0.6, p=0.004).

CONCLUSION:

Using the 6CWT with the Borg scale was reproducible, and it seems to be an appropriate method to evaluate the functional capacity of heart failure patients while making sure that they undergo a submaximal walking test.
Subject(s)

Full text: Available Index: LILACS (Americas) Main subject: Exercise Test / Heart Failure Type of study: Practice guideline / Prognostic study Limits: Humans / Male Language: English Journal: Clinics Journal subject: Medicine Year: 2008 Type: Article Affiliation country: Brazil Institution/Affiliation country: Universidade de São Paulo/BR

Similar

MEDLINE

...
LILACS

LIS

Full text: Available Index: LILACS (Americas) Main subject: Exercise Test / Heart Failure Type of study: Practice guideline / Prognostic study Limits: Humans / Male Language: English Journal: Clinics Journal subject: Medicine Year: 2008 Type: Article Affiliation country: Brazil Institution/Affiliation country: Universidade de São Paulo/BR