Your browser doesn't support javascript.
loading
A influência do uso do "clamp" ou braçadeira no acúmulo de coágulos em drenos pleurais tubulares / The influence of clamp usage on clot deposit formation inside thoracic drains
Lima, Alexandre Garcia de; Rocha, Elen Renate Figueira; Seabra, José Cláudio Teixeira; Mussi, Ricardo Kalaf; Santos, José Geraldo dos; Toro, Ivan Felizardo Contrera.
  • Lima, Alexandre Garcia de; Hospital Estadual Sumaré. Serviço de Cirurgia Torácica e Endoscopia Respiratória. São Paulo. BR
  • Rocha, Elen Renate Figueira; Unicamp. Hospital das Clínicas. Campinas. BR
  • Seabra, José Cláudio Teixeira; Unicamp. Hospital das Clínicas. Campinas. BR
  • Mussi, Ricardo Kalaf; Unicamp. Hospital das Clínicas. Campinas. BR
  • Santos, José Geraldo dos; Unicamp. Hospital das Clínicas. Campinas. BR
  • Toro, Ivan Felizardo Contrera; Unicamp. Hospital das Clínicas. Campinas. BR
Rev. Col. Bras. Cir ; 35(2): 79-82, mar.-abr. 2008. graf
Article in Portuguese | LILACS | ID: lil-482975
RESUMO

OBJETIVO:

Conduziu-se este estudo prospectivo a fim de avaliar-se a influência do uso da braçadeira sobre o acúmulo de coágulos dentro dos drenos pleurais.

MÉTODO:

Os drenos pleurais foram pesados logo após sua retirada, lavados e secados e pesados novamente. A diferença entre a primeira e a segunda pesagem foi admitida como a quantidade de coágulos acumulada.

RESULTADOS:

Houve maior acúmulo de coágulo nos drenos temporariamente obstruídos por braçadeira em relação àqueles não obstruídos.

CONCLUSÃO:

Notou-se, neste estudo, maior acúmulo de coágulo dentro de drenos pleurais obstruídos, mesmo que intermitentemente, o que pode levar ao mau funcionamento de todo o sistema de drenagem. A discussão sobre o correto uso dos drenos pleurais deve ser constante e fazer parte de programas de educação continuada para médicos e enfermagem, a fim de que este sistema, amplamente utilizado e altamente eficiente, seja otimizado.
ABSTRACT

BACKGROUND:

A prospective study was done to evaluate the influence of clamp usage on clot formation inside thoracic drains.

METHODS:

Each drain was weighed soon after removal; they were then washed, dried and weighed again. The difference between the first and second weights was taken as the amount of clot deposit formed.

RESULTS:

We found more clots accumulated inside the drains that were temporarily obstructed by the clamp.

CONCLUSION:

In this study, there were more clots formation inside thoracic drains clamped, even if they were occluded intermittently. This can lead thoracic drains to function improperly. The discussion about the correct usage of thoracic drains must be a subject for educational programs for physicians and nurses, to aim for the safest use of this widely used and highly efficient system.

Full text: Available Index: LILACS (Americas) Type of study: Observational study Language: Portuguese Journal: Rev. Col. Bras. Cir Journal subject: General Surgery Year: 2008 Type: Article Affiliation country: Brazil Institution/Affiliation country: Hospital Estadual Sumaré/BR / Unicamp/BR

Similar