Avaliou-se o potencial de uso reator anaeróbio operado em bateladas seqüenciais com biomassa imobilizada (ASBBR), em escala piloto, no tratamento de água residuária industrial contendo elevadas concentrações de sulfato. O ASBBR, com volume total de 1.2 m³, foi preenchido com carvão mineral como meio suporte para imobilização da biomassa (leito fixo). Foram aplicadas cargas de 0,15; 0,30; 0,65; 1,30 e 1,90 kg SO4-2/ciclo (ou batelada) com duração de 48 h, correspondendo, respectivamente, às concentrações de sulfato no afluente de 0,25; 0,50; 1,0; 2,0 e 3,0 gSO4-2.l-1. Utilizou-se etanol como doador de elétrons para a redução do sulfato. O reator foi operado à temperatura ambiente (29±8ºC), tendo sido obtidas eficiências médias na redução de sulfato entre 88 e 92 por cento em 92 ciclos (275 dias). Os resultados obtidos permitem concluir que o uso de reatores ASBBR constitui-se em alternativa eficiente para a remoção de sulfatos de águas residuárias com características semelhantes às utilizadas neste trabalho.
ABSTRACT
The potential use of an anaerobic sequencing batch biofilm reactor (ASBBR) in pilot-scale for the treatment of a sulfate-rich industrial wastewater was evaluated. The pilot 1.2 m³ ASBBR reactor was filled with mineral coal for biomass immobilization (fixed film). The sulfate loading rates applied were 0.15; 0.30; 0.65; 1.30 and 1.90 kg SO4-2/cycle (or batch). Each cycle lasted 48 h. The influent concentrations were, respectively, 0.25; 0.50; 1.0; 2.0 and 3.0 gSO4-2.l-1. Ethanol was used as electron donor for sulfate reduction. The reactor operated at ambient temperature (29±8ºC), and the mean efficiencies of sulfate removal were in the range 88 to 92 percent in the 92 run cycles. The total operating period comprised 275 days. Based on the results obtained in this research, it could be concluded that the ASBBR can be an efficient alternative for the removal of sulfate from other industrial wastewaters with similar characteristics.
Subject(s)

Full text: Available Index: LILACS (Americas) Main subject: Sulfates / Biological Filters / Coal / Bioreactors / Ethanol / Anaerobic Treatment / Industrial Waste Type of study: Prognostic study Language: Portuguese Journal: Eng. sanit. ambient Journal subject: Environmental Health / Public Health Year: 2008 Type: Article / Project document Affiliation country: Brazil Institution/Affiliation country: USP/BR / Unicamp/BR

Similar

MEDLINE

...
LILACS

LIS

Full text: Available Index: LILACS (Americas) Main subject: Sulfates / Biological Filters / Coal / Bioreactors / Ethanol / Anaerobic Treatment / Industrial Waste Type of study: Prognostic study Language: Portuguese Journal: Eng. sanit. ambient Journal subject: Environmental Health / Public Health Year: 2008 Type: Article / Project document Affiliation country: Brazil Institution/Affiliation country: USP/BR / Unicamp/BR