Your browser doesn't support javascript.
loading
Avaliação da superfície dentinária com o microscópio clínico após remoção de retentor intra-radicular utilizando o ultra-som / Evaluation of dentinal surface with clinical microscope after intra-radicularretainer removal using ultrasound
Benassi, Moacyr; Freire, Rosa Maria; Macedo, Mary Caroline Skelton; Cardoso, Rielson José Alves.
  • Benassi, Moacyr; Centro de Pesquisas Odontológicas São Leopoldo Mandic. Faculdade de Odontologia. Campinas. BR
  • Freire, Rosa Maria; Centro de Pesquisas Odontológicas São Leopoldo Mandic. Faculdade de Odontologia. Campinas. BR
  • Macedo, Mary Caroline Skelton; Centro de Pesquisas Odontológicas São Leopoldo Mandic. Faculdade de Odontologia. Campinas. BR
  • Cardoso, Rielson José Alves; Centro de Pesquisas Odontológicas São Leopoldo Mandic. Faculdade de Odontologia. Campinas. BR
RGO (Porto Alegre) ; 56(3): 267-273, jul.-set. 2008. ilus, tab
Article in Portuguese | LILACS, BBO | ID: lil-495231
RESUMO

Objetivo:

Avaliar o tempo despendido e possíveis linhas de fissura, trincas e outros danos causados na superfície dentinária ao redor do retentor intra-radicular submetido à vibração ultra-sônica para a sua remoção, utilizando o microscópio clínico.

Métodos:

Foram utilizadas 15 raízes de incisivos centrais inferiores bovinos, portadoras de retentores intra-radiculares Flexi-Post nº 3 cimentados com o cimento resinoso RelyX CRA® e incluídas em um alvéolo artificial, envoltas com uma camada de silicone. Os retentores foram submetidos à vibração ultra-sônica com o aparelho ENAC modelo EO-5 na sua potência máxima e, após a remoção, foi realizada uma avaliação a olho nu e outra com o microscópio clínico nos aumentos de 5, 8, 12,5 e 20 vezes.

Resultados:

Os resultados mostraram que nenhuma superfície dentinária apresentou linhas de fissura, trincas ou outros danos, e que o tempo médio para remoção dos retentores foi de 13,25 minutos.

Conclusão:

O ultra-som demonstrou ser um aparelho eficaz e seguro para a remoção de retentores intra-radiculares.
ABSTRACT

Objective:

To evaluate the time spent and possible fissure lines, fractures and other damage caused on the dentinal surface around the intra-radicular retainer submitted to ultrasonic vibration to remove it, using a clinical microscope.

Methods:

The roots of 15 bovine mandibular central incisors were used. These contained Flexi-Post No. 3 intra-radicular retainers cemented with RelyX CRA® resinous cement and were included in an artificial alveolus, surrounded by a layer of silicone. The retainers were submitted to ultrasonic vibration with the ENAC model EO-5 appliance at maximum power, and after removal, an evaluation was made by the naked eye, and another with a clinical microscope, at magnifications of 5, 8, 12.5 and 20 times.

Results:

The results showed that no dentinal surface presented fissure lines, cracks or other damage, and that the mean time for removal of the retainers was 13.25 minutes.

Conclusion:

Ultrasound was shown to be an efficient and safe appliance for intra-radicular retainer removal.
Subject(s)

Full text: Available Index: LILACS (Americas) Main subject: Ultrasonics / Post and Core Technique / Dentin Type of study: Evaluation studies Limits: Animals Language: Portuguese Journal: RGO (Porto Alegre) Journal subject: Dentistry Year: 2008 Type: Article Affiliation country: Brazil Institution/Affiliation country: Centro de Pesquisas Odontológicas São Leopoldo Mandic/BR

Similar

MEDLINE

...
LILACS

LIS

Full text: Available Index: LILACS (Americas) Main subject: Ultrasonics / Post and Core Technique / Dentin Type of study: Evaluation studies Limits: Animals Language: Portuguese Journal: RGO (Porto Alegre) Journal subject: Dentistry Year: 2008 Type: Article Affiliation country: Brazil Institution/Affiliation country: Centro de Pesquisas Odontológicas São Leopoldo Mandic/BR