Your browser doesn't support javascript.
loading
A osteotomia em um plano oblíquo por corte único para correção de deformidades complexas diafisárias de ossos longos: um método para sua realização / Single-cut oblique plane osteotomy to correct complex diaphyseal deformities of long bones: a method for its performance
Christian, Ralph Walter; Mercadante, Marcelo Tomanik.
  • Christian, Ralph Walter; Santa Casa de São Paulo. Departamento de Ortopedia e Traumatologia. Grupo do Trauma. São Paulo. BR
  • Mercadante, Marcelo Tomanik; Santa Casa de São Paulo. Departamento de Ortopedia e Traumatologia. Grupo do Trauma. São Paulo. BR
Rev. bras. ortop ; 43(9): 376-387, set. 2008. ilus, graf, tab
Article in Portuguese | LILACS | ID: lil-496865
RESUMO
A correção das deformidades complexas, aquelas simultaneamente com desvios angular e torcional, é possível por osteogênese e por osteotomias. O presente estudo foi realizado para desenvolver e aplicar um método para a técnica da osteotomia em um plano oblíquo por um único corte, para a correção de deformidades diafisárias complexas em ossos longos (fêmur ou tíbia) e verificar a sua aplicabilidade. MÉTODOS: Este estudo prospectivo envolveu 10 pacientes de ambos os sexos, com idades, entre 17 e 62 anos, que apresentavam deformidades complexas de ossos longos (quatro no fêmur e seis na tíbia) tratados cirurgicamente com osteotomia corretiva pela técnica de corte único em um plano oblíquo. Os pacientes foram avaliados comparativamente no pré e pós-operatório, para a mensuração das deformidades angulares verdadeiras através do método gráfico, a partir de medições nas radiografias do osso deformado, e clinicalmente para deformidade torcional e do comprimento. Também foram observados o tempo de consolidação e as complicações. O planejamento pré-operatório determinou o cálculo do ângulo do corte do osso. Foram confeccionados para cada paciente um modelo artificial em plástico do osso deformado e nele simulada a correção. Foram realizados desenhos do osso com anotação dos principais passos cirúrgicos e a escolha do local e do tamanho do material de síntese. O planejamento pré-operatório orientou a cirurgia. No pré-operatório, os pacientes apresentavam deformidades com valores médios de: deformidade angular verdadeira de 19º; torção de 12º; encurtamento de 1,3cm. RESULTADOS: Após correção, as medidas mostraram um valor médio de: deformidade angular verdadeira de 4º (p = 0,005); torção de 1º (p = 0,005) e encurtamento de 0,6cm (p = 0,027). Três pacientes apresentaram complicações, sendo dois com retarde de consolidação e outro com infecção profunda tardia e retarde de consolidação. CONCLUSÃO: O presente estudo mostrou ser possível estabelecer um...
ABSTRACT
Correction of complex deformities, those with concomitant angular and torsional deviations, can be done by osteogenesis and by osteotomies. This study was performed to develop and apply a method of single-cut oblique plane osteotomy to correct complex diaphyseal deformities in long bones (femur or tibia) and to check its applicability. METHODS: This prospective study involved 10 patients of both genders, ages ranging from 17 to 62, who presented with complex deformities of long bones (four in the femur, six in the tibia) and were surgically treated by corrective osteotomy using the single-cut oblique plane technique. The patients were evaluated comparatively before and after surgery to measure the true angular deformities by a graphic method based on radiographic measurements of the deformed bone, and clinically for the torsional deformity and extension. Time till union and complications were also observed. Pre-operative planning determined the calculation of the bone-cutting angle. For each patient, an artificial model was made of the deformed bone, and the correction was simulated in such model. Drawings of the bone with annotations of the major surgical steps and the choice of the site and size of the synthesis material were made. The pre-operative planning guided the surgery. In the pre-operative stage, the patients had deformities with the following mean values: true angular deformity of 19º; torsion of 12º; shortening of 1.3 cm. RESULTS: After correction, the measurements showed the following mean values: true angular deformity of de 4º (p = 0.005); torsion of 1º (p = 0.005), and shortening of 0.6 cm (p = 0.027). Three patients had complications, two with delayed union, and one with late deep infection and delayed union. CONCLUSION: This study showed that it is possible to set up a reliable and reproducible method for the single-cut oblique plane osteotomy technique to correct complex diaphyseal deformities of long bones.
Subject(s)

Full text: Available Index: LILACS (Americas) Main subject: Osteotomy / Prospective Studies / Cohort Studies / Diaphyses Type of study: Etiology study / Incidence study / Observational study / Prognostic study / Risk factors Limits: Adolescent / Adult / Female / Humans / Male Language: Portuguese Journal: Rev. bras. ortop Journal subject: Orthopedics Year: 2008 Type: Article Affiliation country: Brazil Institution/Affiliation country: Santa Casa de São Paulo/BR

Similar

MEDLINE

...
LILACS

LIS

Full text: Available Index: LILACS (Americas) Main subject: Osteotomy / Prospective Studies / Cohort Studies / Diaphyses Type of study: Etiology study / Incidence study / Observational study / Prognostic study / Risk factors Limits: Adolescent / Adult / Female / Humans / Male Language: Portuguese Journal: Rev. bras. ortop Journal subject: Orthopedics Year: 2008 Type: Article Affiliation country: Brazil Institution/Affiliation country: Santa Casa de São Paulo/BR